3. Clean the prefilter with running water from the inner
surface of the prefilter.
CAUTION:
must not be higher than 4 bars.
CAUTION:
across the filter surface as this will do
damage to the filter.
4. Let the prefilter dry fully.
CAUTION:
100% dry before you install it into the
housing.
5. Install the prefilter, close the prefilter cover and
tighten the cover locks.
If the prefilter cannot be fully cleaned or if it is damaged,
it must be replaced. Refer to
page 20 .
Filter replacement
WARNING:
equipment. Refer to
equipment on page 9 . Dangerous dust can
release into the air during filter replacement.
WARNING:
disconnect the power supply before filter
replacement.
To replace the prefilter
1. Remove the prefilter. Refer to
with water on page 19 .
2. Put the prefilter carefully in a plastic bag.
20
The water pressure
Do not hit or drag items
The prefilter must be
To replace the prefilter on
Use personal protective
Personal protective
Stop the product and
To clean the prefilter
3. Discard the plastic bag correctly. Refer to local
regulations.
4. Install the new prefilter.
If the suction is not sufficient when a new prefilter is
installed, it is necessary to replace the HEPA filter. Refer
To replace the HEPA filter on page 20 .
to
To replace the HEPA filter
The HEPA filter cannot be cleaned. It is always
necessary to replace it with a new HEPA filter. Only use
HusqvarnaHEPA filters.
WARNING:
center or an approved authority is permitted
to replace the HEPA filter.
WARNING:
protective equipment, refer to
protective equipment on page 9 .
WARNING:
filter are dangerous to your health.
WARNING:
no holes in the HEPA filter. A damaged
HEPA filter is a health risk.
WARNING:
filter. If you install a used HEPA filter,
leakage and decreased filtration efficiency
can occur.
CAUTION:
surface of the HEPA filter. This can cause
damage to the HEPA filter.
1. Loosen the 6 screws and remove the HEPA filter
cover.
Only an approved service
Always use personal
Personal
The particles in the HEPA
Make sure that there are
Do not install a used HEPA
Do not touch the inner