A dedicated line and junction box should be used to connect the oven to a 20 A circuit.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE A: Adapting to different types of gas
Burner
Inj. size
1/100mm
192
Semi-Rapid
101
66
66
280
Rapid
129
87
87
130
Inner
70
46
Dual
46
N°2 x 300
burner
Outer
N°2 x 110
N°2 x 69
N°2 x 69
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 11) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap and turn the fixing screw to the right or left until the flame of the burner is regulated in the most
suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
DESCRIPTIVE CAPTION FOR HOB (fig.9)
1. Dual burner
---------------:
blu wire:
Yellow/Green wire:
ROOM VENTILATION – LOCATION AND VENTING.
Gas
Pressure
Type
[mbar]
Town G110
8
Natural G20
20
Butane G30
30
Propane G31
37
Town G110
8
Natural G20
20
Butane G30
30
Propane G31
37
Town G110
8
Natural G20
20
Butane G30
30
Propane G31
37
Town G110
8
Natural G20
20
Butane G30
30
Propane G31
37
DESCRIPTION
connect to L1 (hot)
connect to N (neutral)
connect to GND (ground)
Max Rate
g/h
l/h
kw
-
397
1,75
-
167
1,75
127
-
1,75
125
-
1,75
-
681
3
-
286
3
218
-
3
214
-
3
-
181
0,8
-
76
0,8
58
-
0,8
57
-
0,8
885
3,9
-
419
4.4
298
-
4,1
293
-
4,1
Min Rate
kcal/h
kw
kcal/h
1505
0,44
378
1505
0,44
378
1505
0,44
378
1505
0,44
378
2580
0,75
645
2580
0,75
645
2580
0,75
645
2580
0,75
645
688
0,3
258
688
0,3
258
688
0,3
258
688
0,3
258
3354
1,8
1549
3784
1,8
1548
3526
1,8
1548
3526
1,8
1548
By-pass size
1/100mm
31 reg.
31 reg.
31
31
42 reg.
42 reg.
42
42
27 reg.
27 reg.
27
27
65 reg
65 reg
65
65