Download Print deze pagina

VOLTCRAFT VC131 Gebruiksaanwijzing pagina 55

Advertenties

Beschikbare talen

Beschikbare talen

f) AC voltage measurement
Range
200.0 V
600 V
Input impedance: approx. 10 MΩ.
Frequency response: 50 - 60 Hz.
Accuracy guarantee range: 5~100% of range, short circuit allows least significant digit
<5.
Non-sinusoidal waveforms:
- When the crest factor is 1.0 to 2.0, the accuracy must be increased by 4.0 %.
- When the crest factor is 2.0 to 2.5, the accuracy must be increased by 5.0 %.
- When the crest factor is 2.5 to 3.0, the accuracy must be increased by 7.0 %.
Input voltage: max. 600 Vrms.
g) Resistance measurement (Ω)
Range
200.0 Ω
2000 Ω
20.00 kΩ
200.0 kΩ
2.000 MΩ
20.00 MΩ
Overload protection: 600 V
Resolution
0.1 V
1 V
Resolution
0.1 Ω
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
Accuracy
± (1.5 % + 7)
Accuracy
± (1.0 % + 5)
± (1.0 % + 9)
± (2.5 % + 5)
± (2.5 % + 5)
55

Advertenties

loading

Deze handleiding is ook geschikt voor:

2446476