THE WATER HARDNESS TABLE

German degrees
(°dH)
47 - 50
43 - 46
37 - 42
29 - 36
23 - 28
19 - 22
15 - 18
11 - 14
4 - 10
<4
1) Factory setting
2) Do not use salt at this level.

ADJUSTING THE WATER SOFTENER

Make sure that the appliance is in user mode:
1. Press
.
The indicators
The indicator
The display shows the current setting: e.g.
= level 5.
2. Press
to change the setting. Each pressing
increases the level number by one. After
reaching level 10, the countdown starts again
from level 1.
3. Press on/off to confirm the setting.
If you use multi-tabs containing salt
and the hardness of your water is
lower than 21°dH, you can set the
lowest water softener level. It
deactivates the salt refill indicator.
If you use standard detergent or multi-
tabs without salt, set the proper water
hardness level to keep the salt refill
indicator active.
DEACTIVATING THE RINSE AID EMPTY
NOTIFICATION
Make sure that the appliance is in user mode:
1. Press
.
French degrees
(°fH)
84 - 90
76 - 83
65 - 75
51 - 64
40 - 50
33 - 39
26 - 32
19 - 25
7 - 18
<7
and
are off.
still flashes.
mmol/l
Clarke degrees
8.4 - 9.0
7.6 - 8.3
6.5 - 7.5
5.1 - 6.4
4.0 - 5.0
3.3 - 3.9
2.6 - 3.2
1.9 - 2.5
0.7 - 1.8
<0.7
The indicators
The indicator
The display shows the current setting:
activated.
deactivated.
2. Press
to change the setting.
3. Press on/off to confirm the setting.
When rinse aid chamber is empty, the
rinse aid indicator is on prompting to
refill the rinse aid. If you are using
multi-tabs containing rinse aid and you
are satisfied with the drying result, you
can deactivate the notification.
However, we recommend that you
always use rinse aid for best drying
performance.
If you use standard detergent or multi-
tabs without rinse aid, activate the
notification to keep the rinse aid refill
indicator active.

DEACTIVATING AIRDRY

AirDry improves the drying results with less energy
consumption.
Water softener
level
58 - 63
53 - 57
46 - 52
36 - 45
28 - 35
23 - 27
18 - 22
13 - 17
5 - 12
< 5
and
are off.
flashes.
= rinse aid empty notification
= rinse aid empty notification
10
9
8
7
6
1)
5
4
3
2
2)
1