BEDIENUNGSANLEITUNG
Remedying disturbances
6
P o s s ible c a us e
D riv e s do no t wo rk
The po wer supply cable is no t co nnected
Drives are no t co nnected
P o o r plug co ntact
M o to r unit faulty
Hand switch faulty
D riv e s run o nly in o ne dire c t io n
P o wer failure during mo vement o r the po wer supply
cable has been disco nnected during mo vement
M o to r unit faulty
Hand switch faulty
Drive faulty
M o t o r unit o r ha nd s wit c h do e s no t wo rk
The po wer supply cable is no t co nnected
Hand switch is no t co nnected
M o to r unit faulty
M ains cable is faulty
Hand switch faulty
P o o r plug co ntact
E rro r m e s s a ge s o n t he ha nd s wit c h dis pla y
The wo rd HOT is sho wn o n the display.
The mo to r unit is equipped with pro tectio n against
o verheating. The o verheating pro tectio n has been
activated as a result o f the unit getting to o ho t.
E and an erro r number appear o n the display.
A n internal erro r has o ccurred o n the mo to r unit.
N um be r
D e s c ript io n
00
Internal erro r o n channel 1
01
Internal erro r o n channel 2
02
Internal erro r o n channel 3
1 2
Erro r o n channel 1
1 3
Erro r o n channel 2
1 4
Erro r o n channel 3
R e m e dy
Co nnect the po wer supply cable to the mo to r unit
Co nnect the mo to r cable to the mo to r unit
Co nnect the plugs co rrectly
Co ntact the custo mer service team
Exchange the hand switch
M anual reset (if drives o nly mo ve do wnwards)
Co ntact the custo mer service team
Exchange the hand switch
Co ntact the custo mer service team
Co nnect the po wer supply cable to the mo to r unit
Co nnect the hand switch
Co ntact the custo mer service team
Co ntact the custo mer service team
Exchange the hand switch
Co nnect the plugs co rrectly
Wait until the mo to r unit has co o led do wn and the wo rd
HOT disappears fro m the display. The mo to r unit is
then ready fo r o peratio n again.
P ro ceed acco rding to the list o f erro rs belo w.
R e m e dy
Switch the mo to r unit o ff.
Co ntact the custo mer service team.
Disco nnect the mo to r unit. Remo ve the external sho rt
circuit.
o r
Co nnect the co rrect mo to r to the so cket in questio n.
Switch the mo to r unit back o n.
GB
N um be r
D e s c ript io n
24
Excess current in mo to r M 1
25
Excess current in mo to r M 2
26
Excess current in mo to r M 3
48
Excess current in mo to r gro up 1
49
Excess current in mo to r gro up 2
60
Co llisio n pro tectio n
62
Excess current in the co ntro l
36
P lug detectio n o n mo to r so cket M 1
37
P lug detectio n o n mo to r so cket M 2
38
P lug detectio n o n mo to r so cket M 3
61
M o to r inco rrectly co nfigured
55
Synchro nisatio n o f mo to r gro up 1 no t
po ssible
56
Synchro nisatio n o f mo to r gro up 2 no t
po ssible
67
Vo ltage to o high
81
Internal erro r
Note: The PowerFail Detection function detects power failures and
stores all relevant data before the voltage falls below a critical level.
In a few exceptional cases, this data cannot be stored and when the
control unit is next switched on E81 is displayed and the control clicks
three times.
A manual reset is required to eliminate this error.
JumpFlex
R e m e dy
Remo ve the jammed o bject fro m the range o f
mo vement.
Desk o verlo aded, remo ve the lo ad fro m the desk.
Co ntact the custo mer service team.
Co nnect the co rrect mo to r at the so cket in questio n.
Carry o ut a reset.
Remo ve the lo ad fro m the desk.
Carry o ut a reset. If the erro r co ntinues to be displayed
even after the reset, co ntact the custo mer service
team.
Disco nnect the po wer supply cable and co ntact the
custo mer service team
Carry o ut a reset. Disco nnect the po wer supply cable
and reco nnect it after a few seco nds. If this erro r
o ccurs o n a regular basis, disco nnect the po wer supply
cable and co ntact the custo mer service team.