11
11.1
n
11.1.1
n
Indication
Water leakage
0313853_DRE PLUS_ENNLFR_V4.0, 15-05-2024

Troubleshooting

Errors and warnings

The water heater can have three different kinds of errors:
General errors, which are not displayed
Displayed errors (see 11.1.2), which are divided in two different groups:
-
Lock out errors: when the cause is removed, you can reset the error to resume
operation. The code is displayed continuously and the exclamation mark blinks.
-
Blocking errors: when the cause is removed, the error resets automatically to
resume operation. The code is displayed continuously and the exclamation
mark blinks.
Displayed warnings (see 11.1.3)
Note
It is possible to view the error history of the water heater, refer to Error history (see
9.8).

General errors

Note
For the coding of the connections, refer to the Electrical wiring diagram (see A.5).
Cause
There is a leakage from a threaded wa-
ter connection.
There is a leakage from another nearby
water heater or pipe segment.
There is a leakage from the water heater
tank.
Measure
Tighten the threaded connection.
Trace the leakage.
Contact the supplier of your water heater.