INSTALLATION
Electrical connection
● The oven is manufactured to work with
a one-phase alternating current (230V
1N~50 Hz) and is equipped with a 3
x 1,5 mm
connection lead of 1.5 mm
2
length with a plug including a protection
contact.
● A connection socket for electricity supply
should be equipped with a protection
pin and may not be located above the
cooker. After the cooker is positioned, it is
necessary to make the connection socket
accessible to the user.
● Before connecting the oven to the socket,
check if:
- the fuse and electricity supply are able to
withstand the cooker load,
- the electricity supply is equipped with an
efficacious ground system which meets
the requirements of current standards
and provisions,
- the plug is within easy reach.
Important!
If the fixed power supply cable is damaged,
it should be replaced at the manufacturer
or at an authorized servicing outlet, or by a
qualified person to avoid danger.
13