• The chimney connections of different fireplaces may not be situated opposite one another or at the same
height, since this could also hamper the removal of combustion gases. Two connections of fume outlet
ducts must be situated at least 30 cm away from one another.
• The chimney may not contain too many connections – this hampers the upward pressure. Consult your
chimney-sweep!
• The chimney may not conduct any false air. Check for closed chimney sliders and cleaning hatches in
the cellar or on the roof!
• The outlet duct must be securely attached to the connector pipe.
Transformation from back to top outlet:
54
All manuals and user guides at all-guides.com
(1) dismantle the back protection plate with the 4
screws. Remove the top plate.
(2) dismantle the blanking plate from the lower
top plate, unscrew the fixation bar on the bottom
side, accessible through the outlet opening at the
back.
(3) assemble the blanking plate at the
backoutlet opening of the stove. Watch that
the fixation bar is assembled horizontally.