13 Bijlage
Read parameterization state
Command
Response
aXRPS!
a<value1><value2><value3><-
CR><LF>
Example:
Command
Response
aXRPS!
0+0+0<CR><LF>
Read access protection active mode
Command
Response
aXRAPAM!
a<value> <CR><LF>
Example:
Command
Response
aXRAPAM!
0+1<CR><LF>

Write access protection parameterization unlock

Command
Response
aXWAPPUL <va-
a<value1><CR><LF>
lue1>!
Example:
Command
Response
aXWAP-
0+000<CR><LF>
PUL+123456!

Write access protection parameterization lock

Command
Response
aXWAPPL!
a<value><CR><LF>
54
Description
a: sensor address
<value1>: state, +0 = parametrization, +1 = locked
<value2>: connection state
<value3>: busid
<CR><LF>
Description
Description
a: sensor address
<value>: mode, +0 = none, +1 = device code
(active)
<CR><LF>
Description
Description
a: sensor address
<value1>: 6 numbers (device unlock code)
<CR><LF>
Description
Description
a: sensor address
<value>: VVO-Status +eee
<CR><LF>
VEGAPULS C 21 • SDI-12