Download Inhoudsopgave Inhoud Print deze pagina

Vega VEGAPULS C 21 Handleiding pagina 51

Verberg thumbnails Zie ook voor VEGAPULS C 21:
Inhoudsopgave

Advertenties

Command
aXWSR<value1>!
aXRAPUR!
aXRPS!
aXRAPAM!
aXWAPPUL<value1>!
aXWAPPL<value1>!
aXWAPEC<value1>!
Read Power Operation Mode
Command
Response
aXRPOM!
a<value1><value2> <CR><lf>
Example:
Command
Response
0XRPOM!
0+0<CR><LF>
Write Power Operation Mode
Command
Response
aXWPOM <va-
a<value1><value2> <CR><LF>
lue1>!
Read distance unit
Command
Response
aXRDU!
a<value1><CR><LF>
VEGAPULS C 21 • SDI-12
Response
a<value1><value2><CR><LF>
a<value1><value2><CR><LF>
a<value1><value2><value3><va-
lue4><CR><LF>
a<value1><CR><LF>
a<value1><CR><LF>
a<value1><CR><LF>
a<value1><CR><LF>
Description
Write stage reference
Read access protection unlock result
Read parametrization state
Read access protection active mode
Write access protection parametrization lock
Write access protection parametrization unlock
Write access protection unlock with emergency co-
de
Description
a: sensor address
<value1>: power operation mode, +0 = low power mode,
+1 = normal power mode
<CR><LF>
Description
Description
a: sensor address
<value1>: power operation mode, +0 = low power mode,
+1 = normal power model
<value2>: VVO-Status eee
<CR><LF>
Description
a: sensor address
<value1>: distance unit +0 = unit in [m], +1 = unit in [ft],
+2 = unit in [mm], +3 = unit in [in]
<CR><LF>
13 Bijlage
51

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Sdi-12Vegapuls c 23

Inhoudsopgave