GENERAL INFORMATION
General
These are the mounting instructions for the Novy hood shown on the cover. The manual is a separate booklet that has
been supplied with this hood. Read these instructions carefully before installing and commissioning the hood. It is recom-
mended to have one or more qualified persons carry out the installation.
Symbol
Meaning
Indication
Warning
Safety
Observe the following mounting and safety tips for mounting:
• The installation and electrical connection of the unit shall be carried out by an authorised expert.
• The manufacturer does not accept any responsibility for any damage resulting from faulty building in or connection.
• Carefully take the unit from the packaging and check it for damage before mounting.
• Do not mount the unit in case of any damage.
• Check if all mounting materials have been supplied using the drawings at page 2.
• The unit is intended for household use only (preparation of food) excluding any other domestic, commercial or indus-
trial use.
• Safety can only be guaranteed if the unit is connected to an earth wire in accordance with the required regulations.
• Do not use an extension cord for connecting to the electricity grid.
• Replace defective or damaged parts only with original Novy parts.
• Replace a damaged power cable with an original Novy power cable.
Important before mounting
Page 2 of these mounting instructions show the mounting drawings. Observe the following mounting tips before starting
the mounting activities:
• For easier mounting of the ceiling unit, it is recommended to do this with at least 2 persons.
• Make sure that the construction has sufficient load bearing capacity.
• Position the wall socket in such a way that it is behind the ceiling unit.
• The greater the distance between the hood and the hob, the less easily the cooking vapours will be absorbed by the
hood. Therefore, respect the (recommended) mounting height.
• In order to ensure that the cooking vapours are optimally absorbed, the hood (construction) must cover the entire cook-
ing surface. Centre the hood above the hob for optimum performance.
• For optimal performance, the hob must be larger than the exhaust hood (construction).
Exhaust or recirculation
Before starting any mounting activities, you must have made the choice if you are going to make an exhaust duct to the
outside or if you are going to use the hood as a recirculation hood. In case of an exhaust duct to the outside, carefully
read the section in these mounting instructions for installing the exhaust duct. For recirculation, please separately order
the recirculation kit.
INSTALLATION
Proceed following the mounting drawings on page 2.
PAY ATTENTION TO THE FRONT AND REAR SIDES OF THE COOKER HOOD.
The glass adjustable flap opens forwards. The lighting is installed on the rear.
Carefully look at the mounting drawings!
Preparations for mounting
1
The model 680 is intended for integration into a cabinet of 60 cm wide and the model 686 is for integration into a
cabinet of 90 cm wide.
The mounting height with an induction, electric or ceramic hob is minimum 500 mm and maximum 750 mm.
The mounting height with a gas hob is minimum 650mm and maximum 750mm.
Make a cut-out:
• Type 680: 505 mm x 265 mm.
• Type 686: 805 mm x 265 mm.
• Place the cooker hood as far as possible forward, at least 16 mm.
• The cooker hood is to be mounted in a kitchen cabinet (plate thickness at least 16 mm and maximum 35 mm).
• Make sure there is a socket near the hood. It must be possible at all times to remove the power supply from the
cooker hood.
• Make sure the cabinet door is not lower than the bottom of the cooker hood.
Action
Explanation of an indication on the hood
This symbol indicates an important tip or a dangerous situation.
EN 9