Clean the filter in the water inlet regularly. Detach the water inlet connection,
remove the filter using tweezers (or
something similar), clean the filter under
running water and check whether it is
not damaged. Return all items correctly
and securely to their spots. Never use
the cleaner without a filter.
Keep the ventilation openings of the
machine clean in order not to block the
cooling of the machine.
Regularly grease the O-rings of the
connections to prevent them from drying.
Repairs and inspections must be carried out exclusively by your supplier or an
authorised person trained for that purpose. Improperly executed repairs
invalidate the warranty.
Attention: Never carry out repairs by yourself!
Problems & Solutions
Problem
The machine
does not start
The pressure
fluctuates
The machine
stops working
Cause
-
Plug is not in the socket
-
Defective socket
-
Blown fuse
-
Defective extension cable
-
The pump sucks air
-
The valves are dirty,
worn-out or broken
-
Pump sealing is worn out
-
Blown fuse
-
Incorrect voltage in the
socket
-
Thermal protection is
activated
-
Nozzle is party blocked
Solution
-
Insert the plug into the
socket
-
Try another socket
-
Replace the fuse
-
Try without an extension
cable or use another one
-
Properly seal the
connections and hoses
-
Have the valves replaced
-
Have the pump sealing
replaced
-
Replace the fuse and
perhaps switch off other
machines/appliances
-
Check whether the voltage
corresponds with the
specifications on the type
plate
-
Let the machine cool down
for 5 minutes and
eliminate the source of the
overheating
-
Clean the nozzle
42