4 Programmeren
4.3.17 17-** Terugkopp.optie
Par.
Parameterbeschrijving
nr.
17-1* Incr. enc.interface
17-10 Signaaltype
17-11 Resolutie (PPO)
17-2* Abs. enc.interface
17-20 Protocolkeuze
17-21 Omwenteling (Posities/Omgek)
17-24 SSI-datalengte
17-25 Kloksnelheid
17-26 SSI-dataformaat
17-34 Baudsnelh. HIPERFACE
4
17-5* Resolverinterface
17-50 Polen
17-51 Ingangsspanning
17-52 Ingangsfrequentie
17-53 Transformatieverhouding
17-59 Resolverinterface
17-6* Monitoring en toep.
17-60 Richting terugkoppeling
17-61 Bewaking terugkoppelingssignaal
4.3.18 18-** Data Readouts 2
Par.
Parameterbeschrijving
nr.
18-90 PID Readouts
18-90 Process PID Error
18-91 Process PID Output
18-92 Process PID Clamped Output
18-93 Process PID Gain Scaled Output
4.3.19 30-** Special Features
Par.
Parameterbeschrijving
nr.
30-0* Wobbler
30-00 Wobble Mode
30-01 Wobble Delta Frequency [Hz]
30-02 Wobble Delta Frequency [%]
30-03 Wobble Delta Freq. Scaling Resource
30-04 Wobble Jump Frequency [Hz]
30-05 Wobble Jump Frequency [%]
30-06 Wobble Jump Time
30-07 Wobble Sequence Time
30-08 Wobble Up/ Down Time
30-09 Wobble Random Function
30-10 Wobble Ratio
30-11 Wobble Random Ratio Max.
30-12 Wobble Random Ratio Min.
30-19 Wobble Delta Freq. Scaled
30-8* Compatibility (I)
30-80 d-axis Inductance (Ld)
30-81 Brake Resistor (ohm)
30-83 Speed PID Proportional Gain
30-84 Process PID Proportional Gain
104
Standaardwaarde
4-set-up
[1] RS422 (5V TTL)
All set-ups
1024 N/A
All set-ups
[0] Geen
All set-ups
ExpressionLimit
All set-ups
13 N/A
All set-ups
ExpressionLimit
All set-ups
[0] Gray-code
All set-ups
[4] 9600
All set-ups
2 N/A
1 set-up
7.0 V
1 set-up
10.0 kHz
1 set-up
0.5 N/A
1 set-up
[0] Uitgesch.
All set-ups
[0] Rechtsom
All set-ups
[1] Waarschuwing
All set-ups
Standaardwaarde
4-set-up
0.0 %
All set-ups
0.0 %
All set-ups
0.0 %
All set-ups
0.0 %
All set-ups
Standaardwaarde
4-set-up
[0] Abs. Freq., Abs. Time
All set-ups
5.0 Hz
All set-ups
25 %
All set-ups
[0] Geen functie
All set-ups
0.0 Hz
All set-ups
0 %
All set-ups
ExpressionLimit
All set-ups
10.0 s
All set-ups
5.0 s
All set-ups
[0] Uit
All set-ups
1.0 N/A
All set-ups
10.0 N/A
All set-ups
0.1 N/A
All set-ups
0.0 Hz
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0.100 N/A
All set-ups
MG.33.U3.10 – VLT
®
is een gedeponeerd handelsmerk van Danfoss
®
VLT
AutomationDrive FC 300
High Power Bedieningshandleiding
Alleen
Wijzigen tij-
Conver-
FC 302
dens bedrijf
sie-index
FALSE
-
FALSE
0
FALSE
-
FALSE
0
FALSE
0
FALSE
3
FALSE
-
FALSE
-
FALSE
0
FALSE
-1
FALSE
2
FALSE
-1
FALSE
-
FALSE
-
TRUE
-
Alleen
Wijzigen tij-
Conver-
FC 302
dens bedrijf
sie-index
FALSE
-1
FALSE
-1
FALSE
-1
FALSE
-1
Alleen
Wijzigen tij-
Conver-
FC 302
dens bedrijf
sie-index
FALSE
-
TRUE
-1
TRUE
0
TRUE
-
TRUE
-1
TRUE
0
TRUE
-3
TRUE
-1
TRUE
-1
TRUE
-
TRUE
-1
TRUE
-1
TRUE
-1
FALSE
-1
FALSE
-6
TRUE
-2
TRUE
-4
TRUE
-3
Type
Uint8
Uint16
Uint8
Uint32
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Type
Int16
Int16
Int16
Int16
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint16
Int32
Uint32
Uint32
Uint16