The use of a Franke filter is mandatory to
protect the product against lime scale deposits.
It is mandatory to change the filter based on the
water hardness table.
Water hardness
<10°dh
10-15°dh
15-20°dh
>20°dh
Selection of neutral led intensity
After 60 seconds of not using the tap it will
switch automatically into the sleeping mode
status, 50% led intensity.
To change the sleeping mode setting you have
to follow the below instruction.
1. Activate the tap by pressing the electronic
knob once.
2. Press the electronic knob 5 times.
3. The LED start flashing.
Messages and malfunctions
Boiler messages
LED colour
LED action
Blue
Blinking
Blue
Steady
Orange
Blinking
Red
Blinking
Red
Steady
LED colour
light blue
yellow
light green
purple
4. Turn the knob to the preferred setting by
turning the knob front or backwards:
1: 50% intensity, default
2: 10% intensity
3: Switched off fully
5. After the selection press the electronic knob
for 2 seconds to confirm. The tap flashes
3 times for confirmation.
Description
Boiler does not have water.
Commissioning/system self-check.
System failure; contact Franke service.
Boiler is heating up.
Boiler is fully heated.