EN
Boiler
229
Boiler
Dimensions [H x W]
Net weight
Contents
Voltage
Power
Load
Standby mode max.
IP classification
Storage temperature
Heating time [ΔT 100 K]
Operating pressure (max.)
Operating temperature:
Power supply EU:
Power supply UK:
Declared load profile and typical usage
Water heating energy efficiency class
Water heating energy efficiency
Annual electricity consumption
Thermostat temperature setting
Water quality requirements
pH value
Warning: Only vertical installation of the
boiler is possible (on/off knob on the bottom).
229
4 liters
340 x 229 mm
4.5 kg
4 l
230 VAC
2100 W (+5%/-10%)
9.2 A
14 W
IPX4
<105°C
15 min
800 kPa / 116 psi / 8 bar
0-40°C
Type E+F CEE 7/7 Schuko
Type G/ BS 1363 British 3 Pins
XXS
A
35.15 %
523 kWh
103°C
7 - 9.5
10