14.4 Om de toebehoren van de buitenunit uit te nemen
14.5 Accessoireleidingen: Diameters
RYYQ+RYMQ+RXYQ
VRV IV+ warmtepomp
4P546228-1C – 2021.11
8~12 HP
Controleer of alle accessoires in de unit zitten.
a
b
1×
1×
f
1×
a Algemene voorzorgsmaatregelen met betrekking tot de veiligheid
b Montagehandleiding en gebruiksaanwijzing
c Label hoeveelheid extra koelmiddel
d Informatiesticker installatie
e Label gefluoreerde broeikasgassen
f Meertalig label gefluoreerde broeikasgassen
g Zak met leidingaccessoires
Accessoireleidingen (mm)
Gasleiding
▪
Aansluiting aan de voorkant
ID Øa
ID Øb
▪
Aansluiting aan de onderkant
ID Øa
OD Øb
14~20 HP
c
d
1×
1×
REQUEST FOR THE INDICATION OF INSTALLATION INFORMATION
REQUEST FOR THE INDICATION OF ADDITIONAL REFRIGERANT CHARGING AND LEAK DETECTION OPERATION RESULT
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
1. RECORD OF INDOOR UNIT MODEL AND INSTALLATION SITE
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
No.
1
2
3
4
5
6
7
8
9
10
1. CALCULATION OF ADDITIONAL REFRIGERANT CHARGING AMOUNT
MODELNAME
WHEN RE-CHARGING TOTAL AMOUNT OF REFRIGERANT , CHARGE THE TOTAL OF THE AMOUNT CHARGED AT
CALCULATE THE ADDITIONAL REFRIGERANT CHARGING AMOUNT BASED ON THE FORMULA BELOW BEFORE CHARGING.
INSTALLATION
SITE
SHIPMENT (INDICATED ON THE MACHINE NAMEPLATE) AND THE ADDITIONAL AMOUNT SHOWN AS FOLLOWS :
Total indoor unit
No.
11
12
13
14
15
16
17
18
19
20
kg
capacity connection
MODELNAME
Total indoor unit capacity
50%< CR < 105%
ratio (CR)
0
8HP
10-12HP 14-16HP 18-20HP
0
0
INSTALLATION
OUTDOOR
AMOUNT
ADDITIONAL CHARGING
TOTAL LENGTH OF LIQUID
PIPE SIZE O22.2 x 0.37
PIPE SIZE O19.1 x 0.26
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
PIPE SIZE O15.9 x 0.18
when piping length <30m
50%< CR < 70%
105%< CR < 130%
0.5
0
0.5
0
0.5
0
SITE
No.
21
22
23
24
25
26
27
28
29
30
UNIT
kg
Total indoor unit capacity
70%< CR < 85%
0.3
0.5
0.5
MODELNAME
(m) x 0.37
(m) x 0.26
(m) x 0.18
when piping length >30m
85%< CR < 105%
105%< CR < 130%
0.7
1.2
1
1.5
1.5
1
INSTALLATION
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
SITE
PIPE SIZE O12.7 x 0.12
PIPE SIZE O9.5 x 0.059
PIPE SIZE O6.4 x 0.022
ONLY FOR RYYQ8~20 MODELS
No.
31
32
33
34
35
36
37
38
39
40
(m) x 0.12
(m) x 0.059
(m) x 0.022
kg
RYYQ8~12
0.9
RYYQ14-16
1.1
RYYQ18-20
1.3
MODELNAME
INSTALLATION
SITE
2. RECORD OF ADDITIONAL REFRIGERANT CHARGE AMOUNT AND RESULT OF LEAK CHECK OPERATION
No.
41
42
43
44
45
46
47
48
49
50
MODELNAME
DATE
INSTALLATION
SITE
AMOUNT
No.
51
52
53
54
55
56
57
58
59
60
RESULT LEAK CHECK
MODELNAME
INSTALLATION
DATE
SITE
AMOUNT
No.
61
62
63
64
RESULT LEAK CHECK
MODELNAME
INSTALLATION
SITE
DATE
2. RECORD FOR SETTINGS (CONTENTS SEE INSTALLATION MANUAL)
AMOUNT
RESULT LEAK CHECK
SETTING
VALUE
REMARK
DATE
SETTING
VALUE
REMARK
DATE
DATE
AMOUNT
RESULT LEAK CHECK
3. FOR DETAILS CONCERNING PIPING SELECTION AND CALCULATION OR HOW TO OPERATE THE LEAK DETECTION FUNCTION, PLEASE REFER TO THE INSTALLATION MANUAL.
3. RECORD OF INSTALLATION DATE
DAY
MONTH
YEAR
4. MODEL NAME
5. MANUFACTURING NUMBER
4. AFTER FILLING IN THIS TABLE, PLEASE PUT IT ON THE SWITCH BOX COVER.
6. AFTER EQUIPPING, PLEASE PUT IT ON THE BACK SIDE OF THE FRONT PLATE.
3P328191-1
3P328192-1
g
1×
HP
8
10
12
14
16
18
20
Uitgebreide handleiding voor de installateur en de gebruiker
14
Over de doos
|
e
1×
0.5
1.0
0.5
1.0
1.5
2.0
Øa
25,4
Øb
19,1
22,2
28,6
55