TECHNISCHE GEGEVENS ECODESIGN
ECODESIGN REQUIREMENTS FOR LOCAL SPACE HEATERS
ACCORDING TO DIRECTIVE 2009/125/EC OF THE
EUROPEAN PARLIAMENT AND OF THE COUNCIL
- COMMISSION REGULATION (EU) 2015/1185 -
EDILKAMIN – CHERIE 11 EVO ATC, CHERIE 11 EVO AT
Indirect heating functionality: NO
Direct heat output: 11,0 kW (space heat output)
Indirect heat output: -- kW (water heat output)
Preferred
Other
Fuel
fuel (only
suitable
one):
fuel(s):
Log wood, moisture
no
no
content ≤ 25 %
Compressed wood
with moisture content
yes
no
< 12 %
Other woody biomass
no
no
Non-woody biomass
no
no
Anthracite and dry
no
no
steam coal
Hard coke
no
no
Low temperature coke
no
no
Bituminous coal
no
no
Lignite briquettes
no
no
Peat briquettes
no
no
Blended fossil fuel
no
no
briquettes
Other fossil fuel
no
no
Blended biomass and
no
no
fossil fuel briquettes
Other blend of
no
no
biomass and solid fuel
Characteristics when operating with the preferred fuel only:
Seasonal space heating energy efficiency ηs [%]: 84,6
Energy efficiency index EEI: 125
Item
Symbol
Value
Heat output
Nominal heat output
P
11,0
nom
Minimum heat output
P
3,7
min
(indicative)
Auxiliary electricity consumption
el
0,220
At nominal heat output
max
At minimum heat output
el
0,068
min
In standby mode
el
0,003
SB
Permanent pilot flame power requirement
Pilot flame power
requirement (if
P
N.A.
pilot
applicable)
Contact details
Name and address of the manufacturer or its authorized representative.
Tel. +39 02 937621
Manufacturer: EDILKAMIN SPA
www.edilkamin.it
Via Mascagni 7
mail@edilkamin.it
20020 Lainate (MI) – ITALY
(*) PM = particulate matter, OGCs = organic gaseous compounds, CO = carbon monoxide, NO
(**) Only required if correction factors F(2) or F(3) are applied.
GEBRUIKER/INSTALLATEUR
Inclusa nell'albo dei laboratori altamente qualificati, autorizzati
dal Ministero dell'Università e della Ricerca Scientifica e
Tecnologica ex art. 4 legge n. 46/82 (D.M. 25 maggio 1990)
Space heating emissions at
Space heating emissions at
nominal heat output(*)
minimum heat output(*)(**)
η
s
PM
OGC
CO
NOx
PM
OGC
[%]:
3
mg/m
at 13%O
mg/m
2
84,6
4
<1
42
95
15
Energy efficiency class: A+
Unit
Item
Symbol
Useful efficiency (NCV as received)
Useful efficiency at
kW
η
th,nom
nominal heat output
Useful efficiency at
kW
minimum heat output
η
th,min
(indicative)
Type of heat output/room temperature control
(select one)
single stage heat output, no room
kW
temperature control
two or more manual stages, no
kW
room temperature control
with mechanic thermostat room
kW
temperature control
with electronic room temperature
control
with electronic room temperature
control plus day timer
with electronic room temperature
kW
control plus week timer
Other control options (multiple selections
possible)
room temperature control, with
presence detection
room temperature control, with open
window detection
with distance control option
= nitrogen oxides
x
CO
NOx
3
at 13%O
2
<1
106
80
Value
Unit
88,9
%
93,1
%
NO
NO
NO
NO
NO
YES
NO
NO
YES