Download Inhoudsopgave Inhoud Print deze pagina

Daikin EWAD TZ Gebruikershandleiding pagina 6

Inhoudsopgave

Advertenties

6.5.7
Storing lage afvoer oververhitting ............................................................................................................... 74
6.5.8
Storing Oliedruksensor ............................................................................................................................... 74
6.5.9
Storing sensor Aanzuigtemperatuur ........................................................................................................... 75
6.6
Versnelde stopzetting-alarmen circuit ................................................................................................. 75
6.6.1
Communicatiefout compressorextensie (Alleen W/C units) ........................................................................ 75
6.6.2
Communicatiefout EXV aandrijving (Alleen W/C units) ............................................................................... 76
6.6.3
Storing VFD compressor ............................................................................................................................ 76
6.6.4
Compressor VFD te hoge temperatuur (Alleen A/C-eenheden) ................................................................. 76
6.6.5
Storing sensor condensatiedruk ................................................................................................................. 77
6.6.6
Fout EXV aandrijving van voorverwarmer (Alleen A/C unit) ....................................................................... 77
6.6.7
EXV aandrijving van voorverwarmer niet aangesloten (Alleen A/C unit) .................................................... 77
6.6.8
Storing sensor verdampingsdruk ................................................................................................................ 78
6.6.9
Fout EXV aandrijving (Alleen A/C unit) ....................................................................................................... 78
6.6.10 EXV Motor niet aangesloten (Alleen TZ B units)......................................................................................... 79
6.6.11 Start lage druk mislukt ................................................................................................................................ 79
6.6.12 Ventilator VFD te hoge stroom (alleen A/C units) ....................................................................................... 79
6.6.13 Alarm hoge perstemperatuur ...................................................................................................................... 80
6.6.14 Alarm hoge motorstroom ............................................................................................................................ 80
6.6.15 Alarm hoge motortemperatuur .................................................................................................................... 80
6.6.16 Alarm hoog oliedrukverschil ........................................................................................................................ 81
6.6.17 Hogedruk-alarm .......................................................................................................................................... 81
6.6.18 Lagedruk-alarm ........................................................................................................................................... 82
6.6.19 Alarm lage drukverhouding ......................................................................................................................... 83
6.6.20 Alarm max aantal keer starten (Alleen A/C units) ....................................................................................... 83
6.6.21 Alarm Mechanische hogedruk .................................................................................................................... 84
6.6.22 Alarm waterbevriezing van condensor (alleen W/C units) .......................................................................... 84
6.6.23 Alarm geen druk bij start ............................................................................................................................. 85
6.6.24 Alarm geen drukverandering bij de start ..................................................................................................... 85
6.6.25 Alarm te hoge spanning .............................................................................................................................. 86
6.6.26 Alarm te lage spanning ............................................................................................................................... 86
6.6.27 VFD communicatiefout ............................................................................................................................... 86
7 OPTIES ....................................................................................................................................................... 88
7.1
Totale warmteterugwinning (Optioneel - Alleen A/C units) ................................................................. 88
7.2
Energiemeter met stroombegrenzing (optioneel) ............................................................................... 88
7.3
Snelle herstart (optioneel) ................................................................................................................... 89
7.4
Inverterpomp-kit (optioneel) ................................................................................................................ 89
D-EOMZC00106-17NL
Gebruikershandleiding
6/90
Lucht- en watergekoelde inverter-koelmachines en
warmtepomp
EWAD TZ - EWAD TZ B
EWWD VZ - EWWH VZ
Lucht-
en
watergekoelde
koelmachines en warmtepomp
inverter-

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Ewad tz-bEwwd vzEwwh vzMicrotech-controller

Inhoudsopgave