ERROR CODES
Error Code
The pump's
thermometer
reads the water
temperature below
4°C (40°F).
The pump's
thermometer
reads the water
temperature as
over 50ºC (122ºF).
The pump's
thermometer
connection
has issues.
The pump's
thermometer
reads the water
temperature as
over 52°C (125.6°F).
Wi-Fi module
connection failed.
Probable Causes
The water temperature is
lower than 4°C (40°F).
If the water temperature is
higher than 7°C (44.6°F), the
pump's thermometer is broken.
The water temperature is over
50°C (122°F).
The ambient temperature is
higher than 40°C (104°F) or
the hot tub has been exposed
to direct sunlight for an
extended period.
If the water temperature is
lower than 45°C (113°F), the
pump's thermometer is broken.
The connection between the
temperature sensor and the
PCB may have an issue.
The water temperature is over
52°C (125.6°F).
The ambient temperature is
higher than 40°C (104°F) or
the hot tub has been exposed
to direct sunlight for an
extended period.
If the water temperature is
lower than 45°C (113°F), the
pump's thermometer is broken.
The Wi-Fi module is damaged.
The hot tub is not designed to operate with water
temperatures lower than 4°C (40°F). Unplug the pump
and only re-start the pump when the water temperature
reaches 6°C (42.8°F).
For assistance, please visit the support section on our
website, www.bestwaycorp.com.
The hot tub is not designed to operate with water
temperatures greater than 40°C (104°F). Unplug the
pump and restart it when the water temperature reaches
38°C (100°F) or lower.
Unplug and detach the pump and drain the hot tub.
After 15 minutes, reattach the pump, plug it back in and
restart the heating function. If the alarm appears again,
consider moving the hot tub to another location without
direct sunlight.
For assistance, please visit the support section on our
website, www.bestwaycorp.com.
Unplug the hot tub, wait 5 minutes, and then plug it back
in while switching the pump on. If the alarm appears again,
please visit the support section on our website,
www.bestwaycorp.com.
The hot tub is not designed to operate with water
temperatures greater than 40°C (104°F). Unplug the
pump and restart it when the water temperature
reaches 36°C (97°F) or lower.
Unplug and detach the pump and drain the hot tub.
After 15 minutes, reattach the pump, plug it back in and
restart the heating function. If the alarm appears again,
consider moving the hot tub to another location without
direct sunlight.
For assistance, please visit the support section on our
website, www.bestwaycorp.com.
For assistance, please visit the support section on our
website, www.bestwaycorp.com.
NOTE: Press any button to remove the alarm and
continue to use the hot tub without the Wi-Fi connection.
21
Solutions