Download Print deze pagina

Vetus BOWA0761 Installatiehandleiding pagina 22

Boegschroef

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 7
Bow thruster
The configuration as supplied is for application as a bow thruster.
Stern thruster
Configure a stern thruster by putting the switch on the inside of the
cover into the correct position.
• Reinstall the cover and tighten the glands.
Main power fuse 2
In the connection unit, there
is a main power fuse on the
controller.
This fuse protects the con-
troller and motor against
short
circuit/overloading
and it must remain present
under all circumstances.
When replacing the fuse, the replacement must be of the
same rating.
5.6
Connecting CAN bus (control current) cables
See diagrams from page
97
if multiple panels have to be connected.
The CAN bus power supply must always be connected to
12 Volt (≥10 V, ≤16 V). Use the E-Drive MPE1KB key switch as
power supply.
As required by international standards, all neutral (negative)
conductors of the DC system must be connected to one central
point. This prevents not only dangerous situations and corrosion
problems, but also error messages in the CAN bus system.
22
020811.03
n
ote
n
ote
c
aution
6
Technical data
Type
:
Electromotor
Type
:
For DC systems
:
Current (In)
:
Power consumption :
Rating
:
Protection
:
Insulation class
:
Motor controller
MCV
:
Transmission
Gears
:
Gear ratio
:
Lubrication
: oilbath, outboard gear oil SAE80W or EP 90
:
Propeller
No. of blades
:
Profile
:
Material
:
Rated thrust
:
Control circuit
Fuse
:
Control circuit wires : 2 x 2x 0,5 mm
Extension cable
: 5, 10, 15, 20 or 25 m (16' , 33' , 49' , 66, or 82')
Thrust-tunnel
Steel model
dimensions
: O.D. outside 194 mm, wall thickness 5,6 mm
blasted, coated with: SikaCor Steel Protect.
treatment
:
Suitable for all kinds of protection systems.
Plastic model
dimensions
:
I.D. inside 185 mm, wall thickness 5 mm
material
:
Aluminium model
dimensions
: I.D. inside 185 mm, wall thickness 5,5 mm
material
:
aluminium, 6060 or 6062 (AlMg1SiCu)
Weight
Excl. thrust-tunnel
:
[1]
S2 't' min.  Activation time 't' min. continuously or a max. of 't'
min. per hour at maximum power.
vetus® Installation manual BOW PRO Series Thrusters: BOWA0761
BOWA0761
EC Motor (8VAC-2.7kW)
12 V =
322 A @ 12,0 V
368 A @ 10,5 V
3,9 kW
S2 - 5 min. [1]
IP44
F
MCV1224B + MCVB0761
Bevel gear helical teeth
1,7 : 1
ca. 0.06 litre (2.1 fl.oz.)
6
asymmetrical
polyacetal (Delrin ®)
760 N (76 kgf, 168 lbf )
Blade type fuse 'ATO' 5 A
2
(2 x 2 x AWG20) Twisted pair
glass fibre reinforced polyester
35 kg (77 lbs)

Advertenties

loading

Deze handleiding is ook geschikt voor: