E6
Motor abnormal
To order spare parts
To guarantee an efficient service, make sure you have the following items before you contact our After Sales
Service:
The name or reference of the product.
The manufacturing number shown on the main chassis and on the packing box.
The number of the missing or faulty part shown on the exploded view of the product described in this manual.
D
5. Over rated loaded or the motor is stuck, cause
excessive current, machine will start self-protecting
system. Adjust the machine and restart;
6. Check if the motor has noise from motor or if the
motor / control board were burnt out, if burnt out,
change good motor and control board; Use right
voltage.
1.Check if the motor wire is connect well, reconnect it
2.Check if the motor is defective, change a new motor
After Sales Service