D
Short
Switches the lights on/off at medium intensity.
Long press with
Performs a Filters saturation alarm reset.
all loads off (mo-
tor and lights)
Signals the Metal Grease Filters saturation alarm and the need to
wash them. The alarm is activated after 100 hours of effective hood
operation.
Signals the Activated Carbon Odour Filter saturation alarm. The
alarm is activated after 200 hours of effective hood operation.
E
Short
Delay Function
Activates/Deactivates the Delay function (automatic shutdown of the
Motor and of the lighting delayed by 30').
Cannot be activated with Intensive or 24h function.
Deactivate the function by pressing the same key or press the A key
for about 1 second to shut down the motor.
Long press with
24h Function
light or motor on
Activates/Deactivates the motor in the 24h Air Exchange mode, a
speed that allows suction of 10 minutes every hour, for a 24-hour
cycle.
Long press with
Connected Mode Decoupling
all loads off (mo-
The procedure for deleting all devices compatible with the Connected
tor and lights)
Mode previously associated with the Connected Mode Coupling func-
tion starts.
F
Short
Wi-Fi connection
Activates/Deactivates the Wi-Fi Connection function.
Note: the Wi-Fi function is automatically activated when the user re-
quests the Wi-Fi configuration procedure.
Long press with
Wi-Fi configuration
all loads off (mo-
Activates/Deactivates the Wi-Fi set-up procedure.
tor and lights)
Before starting the procedure, use the Franke@Home App to re-
gister with the Franke IOT system. Then follow the instructions to add
a new device and register the domestic router.
If the procedure is not successfully completed within a few minutes,
deactivate it by long pressing the key again, then make another at-
tempt. The hood will nonetheless abandon the procedure if it is not
successfully completed within 10 minutes.
G
Short
AUTO Mode
Activates/Deactivates the Automatic operating mode.
AUTO mode is deactivated whenever any other keys are pressed.
Cannot be activated with Intensive, Delay or 24h on.
Thanks to the presence of the Air Quality Sensor, an algorithm is
able to modulate the speeds based on the quality level of the intake
air.
WARNING: The algorithm function is optimised for the most common
types of cooking. Uncommon preparations may produce a non-optim-
ised response.
Long press with
Activates/Deactivates the Activated Carbon Filters alarm.
all loads off (mo-
tor and lights)
Fixed
The display shows F 3
times, indicating that the
filter reset has been
completed.
With the motor off, the
display shows F + 1
multiple times altern-
ately.
With the motor off, the
display shows F + 2
multiple times altern-
ately.
LED A remains lit (fixed)
and LED E lights up.
The display shows an
animation.
LED A remains lit (fixed)
and LED E flashes. The
display shows an anim-
ation.
Upon successful com-
pletion of the procedure
all the LEDs flash 5
times.
Flashing:
connection to domestic
network in progress.
Fixed:
Wi-Fi connection activ-
ated
The display shows an
animation:
configuration procedure
in progress.
Upon confirmation that
the procedure was suc-
cessful, all the LEDs will
light up for 2 seconds.
Fixed:
AUTO mode activated.
Off:
AUTO mode temporarily
deactivated.
With the motor off, the
display shows F + 2
alarm activated.
With the motor off, the
display shows F + 0
alarm deactivated.
13