Installation
Installation site
WARNING
Consult a specialist, if there is any doubt on the
load carrying capacity of the installation site.
Prior to the installation, check if the wall or ceiling at
the installation site has sufficient load carrying capac-
ity. Special care needs to be taken if the installation
shall be carried out at an insulated wall or ceiling, as
the increasing demands on thermal insulation reduce
the tensile forces of anchor bolts and other fastenings.
Make sure the installation site is straight and allows
the correct positioning of the awning in terms of
height and the desired pitch angle of the awning.
Wind resistance classes
This awning is designed to withstand Beaufort force 5
wind speeds, which equals wind resistance class 2.
The combination of wall type and mounting material
used at your installation site might result in a lower
wind resistance class for your awning.
WIND RESIST-
BEAUFORT
WIND SPEED
ANCE CLASS
FORCE
0
1-3
up to 19 km/h
1
4
20 - 27 km/h
2
5
28 - 37 km/h
3
6
38 - 48 km/h
102
|
ENGLISH
WARNING
To prevent risks during installation, the installer
must have sufficient knowledge in the following
qualifications:
•
Occupational safety and health (OSH), opera-
tional safety and accident prevention regula-
tions given by the Employer's Liability Insurance
Association.
•
Handling and transport of long and heavy com-
ponents.
•
Handling of ladders and scaffolding.
•
Evaluation of basic structures of a building.
•
Handling of tools and machines.
•
Handling and installation of fastening equip-
ment.
•
Commissioning and operation of products.
If not every qualification can be covered by the in-
staller, seek for a professional installation special-
ist to perform the installation.
An installation specialist will be able to provide infor-
mation about the wind resistance class the awning can
withstand after the installation. The table below can
be used to identify different wind speeds by observing
tree movement:
IMPLICATION
Leaves and small twigs constantly moving
Small branches begin to move, loose paper is raised
from the ground
Branches of a moderate size move, small trees in leaf
are sway
Large branches in motion, umbrella use becomes dif-
ficult
Mounting material
A fully extracted awning has to withstand extreme
loads at its fastenings. Depending on the wall type
at the installation site, the correct fastening must be
selected in order to ensure a secure fixation.
The table below provides a basic recommendation
of fastenings for different wall types, but a specialist
should be consulted in order to figure out, which fas-
tening is the appropriate one. He will also be able to
inform about the wind resistance class the awning can
withstand after the installation.
WALL TYPE
LOCATION
Concrete
Ceiling
Concrete / C20-C25
Ceiling / insulated
Wall
Wall / insulated
Solid brick
Wall
Clay brick / MZ
Wall / insulated
Sand-lime brick / KS
Perforated brick
Wall
Clay brick / HLZ
Wall / insulated
Sand-lime brick / KSL
Aerated concrete
Wall
Gas concrete/isolated
Wall / insulated
Double wall
Wall / insulated
For every mounting material, the specifications of the fastening manufacturer must be observed, e.g. drill
sizes, distances to edges, tensioning torques, drying times etc.
Technical data
MODEL
10179647
12209704
12209708
max. width
1950 mm
max. extension
1500 mm
Weight fabric
280 g/m²
Weight complete
15.2 kg
WARNING
To meet the wind resistance class mentioned in
the declaration of conformity, the installed awn-
ing needs to fulfil these requirements:
•
The awning is installed with the recommended
type and number of brackets.
•
The awning is installed under consideration of
the given fastening pull-out forces.
•
The instructions of the fastening manufacturer
have been respected during installation.
The combination of wall type and mounting mate-
rial used at your installation site might result in a
lower wind resistance class for your awning.
FASTENING
e.g. TOX Anchor bolt S-Fix Pro 1 A4
e.g. TOX Thermo Proof Plus
e.g. TOX Anchor bolt S-Fix Pro 1 A4
e.g. TOX Thermo Proof Plus
e.g. TOX Masonry Set Wallix
e.g. TOX Thermo Proof Plus
e.g. TOX Masonry Set Wallix
e.g. TOX Thermo Proof Plus
e.g. TOX Mosorny Set Wallix
e.g. TOX Thermo Proof Plus
e.g. TOX Thermo Proof Plus
WARNING
10179650
10179661
10179662
12209705
12209706
12209709
12209710
12209712
12209713
12209715
12209720
2950 mm
3500 mm
3950 mm
2500 mm
2500 mm
3000 mm
280 g/m²
280 g/m²
280 g/m²
22.1 kg
24.5 kg
29 kg
ENGLISH
10179648
12209707
12209711
12209714
12209721
5000 mm
3000 mm
280 g/m²
33 kg
|
103