Error codes:
Err101: Replace the battery
Err104: Calculation error
Err152: Temperature is too high: > 40°C
Err153: Temperature is too low: < 0°C
Err154: Outside the measuring range
Err155: Received signal too weak
Err156: Received signal too strong
Err157: Incorrect measurement or background is too bright
Err160: The device is moving too much to measure
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing
for longer periods. Store the device in a clean and dry place.
Calibration
The meter needs to be calibrated and tested on a regular basis to ensure
it produces accurate measurement results. We recommend carrying
out calibration once a year. Contact your distributor or the
UMAREX-LASERLINER service department.
Technical Data
(Subject to technical changes without notice. Rev21W40)
Distance measurement
Precision (typical)*
Inside measurement range**
Angle measurement
Measuring range
Resolution
Precision
Laser class
Laser wavelength
Operating conditions
Storage conditions
Radio module
operating data
18
EN
± 2 mm
0,1 m - 50 m
± 90°
0,1°
0,1°
2 / < 1 mW (EN 60825-1:2014/AC:2017)
650 nm
-10°C ... 40°C, max. humidity 80% rH,
no condensation, max. working altitude
2000 m above sea level
-20°C ... 70°C, max. humidity 80% rH
IEEE 802.15.4. LE ≥ 4.x (Digital
Connection) interface; Frequency band:
ISM band 2400–2483.5 MHz, 40 chan-
nels; Transmission power: max. 10 mW;
Bandwidth: 2 MHz; Bit rate: 1 Mbit/s;
Modulation: GFSK/FHSS