EN
Special case: adjusting the position of the door for partial
opening (Fig. 32)
Select setting "P6" and validate by pressing "OK".
Move the door to the desired partially open position:
- Pressing and holding the "-" button will close the door.
- Pressing and holding the "+" button will open the door.
- Validate by pressing "OK".
- Exit the menu with "SET".
Forced mode (Fig. 33)
This function makes it possible to manipulate the door at any moment (loss of remote control,
photoelectric cell fault, etc.).
Door stationary:
- press the "-" button to close it
- press the "+" button to open it.
Door moving: press the "-" or "+" button to stop the door.
Memorising the remote control for operation in «Partial
opening» mode (Fig. 34)
Memorising the remote control for controlling remote lighting
(Fig. 35)
Memorising a Telis or similar type remote control (Fig. 36)
8 SPECIAL OPERATION
Refer to the user manual.
Adding a remote control without accessing the motor head (see
user guide Fig. 12a et 12b)
9 CLEARING REMOTE CONTROLS AND ALL
SETTINGS
9.1 Clearing remote controls - Fig. 37
Press the "PROG" button until the light blinks (7 s).
This clears all of the remote controls memorised.
9.2 Resetting all settings - Fig. 38
Press the "SET" button until the light goes out (7 s).
This clears all previously stored settings and returns them to their default values.
10 LOCKING PROGRAMMING FIG. 39
The keypad must be locked to ensure the safety of the end-users.
Non-observance of this instruction can result in serious injury to persons, e.g. when
trapped by a door.
Pressing the "SET", "+", "-" buttons:
- start by pressing "SET".
- the "+" and "-" buttons must be pressed simultaneously within 2 seconds.
To access programming mode once again, repeat the same procedure.
11 REFITTING COVERS FIG. 40
Position the aerial and fit the covers.
To ensure proper remote control range, the aerial must be fitted in one of the
two positions shown in Fig. 40.
9
WARNING
12 TROUBLESHOOTING
12.1 Operating codes displayed
Code
Description
Waiting for a command
Door opening
Waiting for the door to close
Door closing
Obstacle detection
Safety input active
Pedestrian door safety contact
active
Safety mechanism self test
Permanent hardwired control
Working from back-up battery
Waiting for a command
12.2 Programming codes displayed
Code
Description
Comments
Awaiting setting
Pressing the "SET" button for 2 s starts the learning
mode.
Learning mode
Pressing the "OK" button starts the learning cycle: the
S2 display blinks during the entire cycle.
Pressing the "+" or "-" buttons will control the motor
in forced mode.
Awaiting remote
Pressing a button on the remote control allocates this
control memorisation
button to the motor total opening control.
for operation in total
Pressing "PROG" once more switches to "awaiting
opening
remote control memorisation for operation in partial
opening: F1" mode.
Awaiting remote
Pressing a button on the remote control allocates this
control memorisation
button to the motor partial opening control.
for operation in partial
Pressing "PROG" once more switches to "awaiting
opening
remotely controlled lighting memorisation: F2" mode
Awaiting remotely
Pressing a button on the remote control allocates this
controlled lighting
button to the remotely controlled lighting control.
memorisation
Pressing "PROG" once more switches to "awaiting
remote control memorisation for operation in total
opening: F0" mode.
Dexxo Pro RTS
Comments
Displayed during obstacle detection then
for 30 s.
Displayed a er a movement request or
during movement, when the safety input
is active.
This display is maintained as long as the
safety input is active.
Displayed a er a movement request or
during movement, when the pedestrian
door contact is open.
The display is maintained as long as the
pedestrian door contact remains open.
Displayed during safety mechanism self
tests.
Indicates that the permanent hardwired
control input is activated (contact closed).
Commands from radio remote control
units are inhibited.