7.6) STATISTICS MENU

Used to view the version of the board, the total number of operations (in
hundreds), the number of transmitters memorized and the last 30 errors (the
first 2 digits indicate the position, the last 2 give the error code). Error 01 is the
most recent.
7.7) PASSWORD MENU
Used to set a password for the board's wireless programming via the U-link network.
With "PROTECTION LEVEL" logic set to 1,2,3,4, the password is required to access
the programming menus. After 10 consecutive failed attempts to log in, you will
need to wait 3 minutes before trying again. During this time, whenever an attempt
is made to log in, the display will read "BLOC". The default password is 1234.
8) OPEN IN OTHER DIRECTION
9) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD
PROGRAMMER VERSION> V1.40 (Fig. B) Refer to specific manual.
10) RADIO-RECEIVER (Fig. B)
The board comes ready for connection of removable radio-receiver.
The receiver's channel 1 controls input IC1.
The receiver's channel 2 controls terminals 26-27.
11) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
The use of some models causes lowered radio capacity. Adjust the system using
an appropriate antenna tuned to 433MHxz.
TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
0
120
TCA
TRF. L GHT.
1
 180
CLR. T
partial
1
99
opening
1
99
out prog 1
1
99
out prog 2
1
99
OP. F ORCE
1
99
CLS. F ORCE
Rev. Dis.
0
200
space
ainte-
0
250
nance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "B" - LOGIC MENU - (LOGIC)
Logic
Definition
Automatic Closing
TCA
Step-by-step
STEP-BY-STEP
movement
OVE NT
16 -
LEO B CBB 3 230 L01
INSTALLATION MANUAL
Default
Personal
Definition
10
Automatic closing time [s]
Time-to-clear traffic light
 40
zone [s]
40
Partial opening [%]
Output 1, programmable
50
in height
Output 2, programmable
50
in height
Leaf force during opening
80
[%]
Leaf force during closing
80
[%]
0
Reverse disabling space
Programming number of
operations for maintenance
0
threshold
[in hundreds]
Cross out
Default
setting
used
0
 
Time
0
 
12) RESTORING FACTORY SETTINGS (Fig.G)
WARNING: this operation will restore the control unit's factory settings and all
transmitters stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to
people and animals.
- Cut off power to the board (Fig.G ref.1)
- Open the Stop input and press the - and OK keys together (Fig.G ref.2)
- Switch on the board's power (Fig.G ref.3)
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.G ref.4)
- Wait for the procedure to finish (Fig.G ref.5)
- Procedure finished (Fig.G ref.6)
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
For best results, it is advisable to run the autoset function with the motors idle (i.e.
not overheated by a considerable number of consecutive operations).
Waiting time before automatic closing.
Time-to-clear for the zone run through by traffic controlled by the traffic light.
Adjusts partial opening percentage compared to total opening in "Partial open" mode.
The output set as AUX=17 (see the AUX outputs Configuration table) gets activated when the
door exceeds the opening percentage set in this parameter (1% = door closed, 99% = door open).
The output set as AUX=18 (see the AUX outputs Configuration table) gets activated when the
door exceeds the opening percentage set in this parameter (1% = door closed, 99% = door open).
Force exerted by leaf/leaves during opening.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety devices where
necessary.
Force exerted by leaf/leaves during closing.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety devices where
necessary.
Disables obstacle/curb detection near the limit stop in closing
0 = no disabling 200 = disabling Maximum
WARNING: It affects impact force directly: make sure that current safety require-
ments are met with the set value (*). Install anti-crush safety devices where necessary.
Allows you to set a number of operations after which the need for maintenance will be re-
ported on the AUX output configured as Maintenance or Flashing Light and Maintenance .
0
Logic not enabled
1
Switches automatic closing on
Inputs configured as Start E, Start I,
0
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
1
Ped operate with 3-step logic. Pulse
during closing reverses movement.
Inputs configured as Start E, Start I,
2
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
Description
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURING
CLOSING
OPEN
CLOSES
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
OPENS
4 STEP
OPENS
STOPS
CLOSES
OPENS

Advertenties

Inhoudsopgave
loading

Inhoudsopgave