4. Technical specifications
Mains voltage:
Frequency:
Max. power input:
Fuse (rear):
Output voltage:
Max. output current:
Maximum power output:
Cooling:
Polarity:
Short-circuit protection:
Mains connection:
Accuracy of display:
Voltage stabilisation:
Load stabilisation:
Output voltage:
Ripple, peak-peak:
Remote on/off:
Internal power supply:
Ambient temperature:
Operating environment:
Input/output connectors:
Options:
5. Installation
5.1. Checks
- Check that the generator is undamaged and that you have received the correct model.
- Check that the details on the packing slip correspond with the details shown on the product
received.
If you have any problems and/or if in doubt:
Please contact SIMCO or your regional agent.
9752090250 ECM Lite
All manuals and user guides at all-guides.com
90 – 130 VAC or 207 - 253 VAC
47 - 63 Hz.
ECM - N (P) Lite
48 W
630 mAT
0 - 20 kV DC
0.7 mA
14 W
convection
N = negative/P = positive
output electronically protected at max. output current
Euro connector IEC-320
1 % of max. value ± 2 digits
2 % of max. output voltage with a mains voltage of
90 – 130 VAC / 207 - 253 VAC
2 % of maximum output voltage at load fluctuations
between 0 and max.
can be set between 0 kV and max. output voltage
10 % of maximum output voltage at maximum load
0V = off, 12 V = on (typical)
Control voltage specifications:
10 VDC, 10 mA min.
25 VDC, 25mA max.
12 VDC (+/- 20%), 20mA (U
for remote on/off and external overload signalling, if
necessary
0 - 40 °C
vibration-free installation
4x HV output
1x I/O Sub-D 25-pin
Remote control functions:
- switching high voltage on/off
- output voltage regulation
24
= 0.5V
max.)
ripple
tt
11/03