4. Technical specifications
Mains voltage:
Frequency:
Max. power consumption: 240W
Fuse (back):
Output voltage:
Max. output current:
Maximum power output:
Cooling
Polarity:
Short-circuit protection:
Mains connection:
Accuracy of display:
Voltage stabilisation:
Load stabilisation:
Output voltage:
Ripple, peak-peak:
Remote on/off:
Internal power supply:
Ambient temperature:
Operating environment:
Input/output connectors
Options:
5. Installation
5.1. Checks
- Check that the generator is undamaged and that you have received the correct version.
- Check that the details on the packing slip correspond with the details shown on the product
received.
If you have any problems and/or if in doubt:
Please contact SIMCO or your regional agent.
97.52.09.0230 ECM 30 /ECM 60
All manuals and user guides at all-guides.com
85 to 264 V
47 – 63 Hz.
ECM 30N (P)
3.15 AT
0 – 30 kV DC
5 mA
150 W
convection
N = negative / P = positive
output electronically protected at max. output current
using Euro connector IEC-320
1 % of max. value ± 2 digits
2 % of maximum output voltage at mains voltage
fluctuations between 85 and 264 V.
2 % of maximum output voltage at load fluctuations
between 0 and max.
can be set between 0 kV and max. output voltage
5 % of maximum output voltage at maximum load
0V = off, 12 V = on (typical)
Control voltage specifications:
10 VDC, 10 mA min
25 VDC, 25mA max
12 VDC(+/- 20%), 20mA (U
for remote on/off and external overload signalling, if
necessary
0 – 40 °C
vibration-free installation
4x HV output
1x I/O Sub-D 25-pin
Remote control functions:
- switching on/off at high voltage
- output voltage read out
- input current read out
- output voltage control
- overload indication (maximum load 50VDC, 50mA)
27
ECM 60N (P)
240W
3.15 AT
0 – 60 kV DC
2.5 mA
150 W
convection
= 0.5V
Max)
ripple
tt
03/04