E605
Guide for the installer

5.1. CN1 TERMINAL BOARD

5.1.1. p
(F
oWer supply
Terminals "1 & 2". Connect, to these terminals, the two cables coming from the 230 V~ or 115 V~ power supply line.
Connect the neutral wire to terminal "2" and the phase to terminal "1".
5.1.2. e
(F
. 2)
Arthing
ig
Terminals " " ". Connect the yellow-green power cable to this terminal.
This connection is absolutely necessary for correct operation of the control unit.

5.2. CN2 TERMINAL BOARD

5.2.1. m
(F
. 3)
otor
ig
Terminals " "4 & 5". 24 V
output. Connect the motor power cables to these terminals. The following table shows the connection sequence
for the motor cables according to the installation type:
Left hand installation (the beam closes on the operator right)
Right hand installation (the beam closes on the operator left)
5.2.2. o
pening trAvel limit
Terminal " "6". Connect, to this terminal, the wire of the NC contact of the opening travel limit. The activation of this contact enables to identify
the beam in open position. The status of this input is signalled by LED FCA.
5.2.3. t
rAvel limit common contAct
Terminal " "7". Connect, to this terminal, the wires of the common contact of both travel limits FCA and FCC.
This input must be used only for the connection of both travel limits common contact. Do not use it as a negative contact
of other accessories.
5.2.4. c
losing trAvel limit
Terminal " "8". Connect, to this terminal, the wire of the NC contact of the closing travel limit. The activation of this contact enables the
identification of the beam in closed position. The status of this input is signalled by LED FCC.
Both travel limits FCC and FCA are only used to identify the rod position.
The connection of both travel limits is absolutely necessary for correct operation of the control unit.
The table below shows the connection sequence of both travel limit wires according to the installation type:
Left hand installation (the beam closes on the operator right)
Right hand installation (the beam closes on the operator left)

5.3. CN3 TERMINAL BOARD

5.3.1. F
(F
lAshing lAmp
Terminals " "12 & 15". Output 24 V
parts) which must be positioned on the operator's sides. Both strips stay OFF when the rod is at rest, both at opening and closing, whereas
they flash when the rod is moving. Before each manoeuvre, the strips pre-flash for 0.5 seconds (not modifiable) to indicate the upcoming
beam movement.
If the "service request" function was activated (see paragraph 9), the strips perform a rapid pre-flashing sequence of 5 seconds at the end
of the closing movement. See paragraph 9.1 for the operation of this function and for the cycle resetting.
As an alternative you can connect an external steady light flashing lamp with max. power supply of 24 V
is controlled by the control unit.
During the control unit programming phase and the adjustment of the function parameters, the flashing lamp stays ON with steady
beam.
When connecting the lamp, please observe the polarity of the terminals - terminal 12 is the positive pole.
5.3.2. i
(F
ndicAtor light
Terminals "13 & 15". Output 24 V
After connection, the lamp will operate as follows:
Indicator light OFF = Automated system closed
Indicator light ON = Rod open
Indicator light flashing rapidly = Rod opening
Indicator light flashing slowly = Rod closing

5. CONNECTIONS AND OPERATION

. 2)
ig
Installation type
FcA (F
. 3)
ig
com (F
. 3)
ig
Fcc (F
. 3)
ig
Installation type
. 4)
ig
max.15 W. Connect, to these terminals, the power cables of both luminous strips (sold as separate
. 4)
ig
max. 5 W. Connect, to these terminals, the lamp (if any) for the remote monitoring of the beam status.
Cable colour
Terminal 4
Terminal 5
Blue
Brown
Brown
Blue
Cable colour
Terminal 6
Terminal 7
Brown
Blue
Black
Blue
15 W. The flashing operation
Terminal 8
Black
Brown