Translation of original operating instructions
4. Technical Data
Model
Mains voltage / frequency
Nominal performance
Protection type
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
Max. delivery height (H
)
max
Max. submersion depth
Max. size of the solids being pumped
Max. fluid temperature normal use (T
Max. fluid temperature (T
max
Max. fluid temperature short termed (T
Motor submerged S1
Motor emerged short time operation S2 (min. 30 cm submerged)
Motor emerged intermittent operation mode S3
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
Min. self-priming level (A)
2)
Min. suction level (B)
2)
Cut-in level (C)
2)
Cut-out level (D)
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced outlet.
2)
The values between brackets refer to the illustrations given at the end of these operating instructions.
3)
When water temperature exceeds 50 °C, but not exceeds 90 °C, it only operates 4 min, then stop until the
motor completely cool down.
5. Installation
5.1.
General installation information
During the entire process of installation, the device must not be connected to the
electrical mains.
The pump and the entire connection system have to be protected from frost.
All connection lines have to be perfectly tight since leaking lines may affect the performance of the
pump and cause considerable damage. If required, please use a suitable sealant to make the
installation airtight.
Avoid excessive force when tightening the screwed connections, which can lead to damage. When
laying the connection pipes, you should make sure that the pump is not exposed to any form of
weight, vibration or tension. Moreover, the connection lines must not contain any kinks or an adverse
slope.
Please observe the illustrations, too, which are contained as an attachment at the end of the present
operating instructions. The numeric and other details included in brackets below refer to these
illustrations.
1)
)
max
) (completely submerged)
≤ 4 min)
3)
max
2)
(completely submerged)
3
EXTREMA CUT 300/18 CX
230 V~ / 50 Hz
2.000 Watt
IPX8
57.29 mm (2"), female
18,000 l/h
1.8 bar
18 m
7 m
50 mm
35 °C
50 °C
90 °C (max. 4 min.)
continuous operation
30 min
2,5 min on, 30sec. off
15, evenly distributed
10 m
H07RN8-F
~ 21.1 kg
115 mm
70 mm
550 mm
215 mm
27 x 19 x 45 cm
30277