MAINTENANCE AND TROUBLESHOOTING
1
MAINTENANCE
Before
carrying
operation, disconnect the device from the
power supply.
Frequently check the installation in order to
detect any sign of deterioration. Do not use the
device if any repair or adjustment is necessary.
A record of all repairs and maintenance operations
must be kept. The owner of the facility must keep
these records safe.
2
MAINTENANCE MENU
1 Press ENTER to access the main programming menu.
The display lights up and D1 flashes.
2 Press the buttons ^ and
ç (maintenance menu). Press ENTER to confirm. D2
flashes.
3 Press the buttons ^ and
parameter appears (see table). Press ENTER to
confirm. D3 and D4 flash.
D1
D2
Parameter
ç
0
Programming lock key
Be sure to remember any
key used, for future access
to the programming
ç
1
Total operations completed
ç
2
P a r t i a l
completed
ç
3
Restore to default values,
o p e r a t i o n , r a d i o a n d
configuration
3
COMMUNICATIONS MODULE
These functions are only available if the optional
communications module has been installed.
1 Press ENTER to access the main programming menu.
The display lights up and D1 flashes.
2 Press the buttons ^ and
t flashing. Press ENTER to confirm. D2 flashes.
D1
D2
Parameter
t
0
FTP communication
1
GSM signal strength
66
Installation Guide
out
any
maintenance
until D1 shows the letter
V
until the required D2
V
D3
D4
0
0,1
X
X
o p e r a t i o n s
X
X
r
S
until D1 shows the letter
V
D3
D4
o
ç
X
X
Every six months
1 Check that the operation and safety devices
(photocells or safety strips), as well as their
installation, have not suffered any damage from the
weather or external agents.
2 Check the operation of the flashing light.
3 Check the device for normal operation.
4.a ç000 programming lock key disabled, ç001
programming lock key enabled (press the buttons ^
and
to choose the required option).
V
4.b ç1XX total operations performed
4.c ç2XX partial operations completed
4.d Restore to default values
5 Press ESC to return.
Options or values
The preset option is 0000 (no key). If any figure is
changed, this is considered a key.
Select the required key (starting with D1) using UP and
DOWN. Press ESC to cancel or ENTER to confirm and move
to D2, and so on.
Indicates the cycles completed, multiplying the indicated
figure by an amount, for example:
68
indicates 6,800 cycles completed
6: 8
indicates 68,000 cycles completed
Indicates the hundreds of cycles completed. This can be
reset by pressing ST1, ST2 and ENTER at the same time.
With the display showing ç3rS (with 3 flashing), press
ENTER and b0rr will flash. Hold down ENTER until D1
shows b, restoring all programming menu values to
default.
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm.
t0oç: allows communication with the server.
t1XX: indicates GSM signal strength.
4 Press ESC to return.
Options or values
Immediate communication with the server
Indicates signal strength
until the required D2
V