3
PROGRAMMING SEQUENCE
General navigation through the programming parameters and menus
Display
?
ENTER
á
or
ESC
à
CL
It is necessary to close the gate or disconnect and
reconnect the control board in order to access the
programming menus.
Press the ENTER button to access the programming
menus. The display shows "C" flashing.
The ^ and
keys can be used to select the required
V
values, which should be confirmed by pressing
ENTER. Pressing ENTER will confirm the value and
move onto the next display.
Use ESC to go back to the previous display.
To leave the programming menu, press ESC several
times until the display shows CL.
Checking turning direction
D1
ENTER
á
C
ESC
à
Select the value
using ^ and
V
ST2
ST1
O239A
STARTING UP AND PROGRAMMING
D2
ENTER
á
1
ENTER
(confirming)
à
Select the value
using ^ and
ESC
V
(unconfirmed)
à
All the programmable functions are organised in four menus,
which must be programmed in the following order:
1 Initial Conditions menu (D1=C, page 58), where
the installation characteristics are defined (number
of operators, turning direction, etc).
2 Programming menu (D1=P, page
programme the radio codes and the gate open/
close.
3 Main Functions menu (D1=F, page 62), to select
operation mode, standby time and pedestrian
opening.
4 Advanced Functions menu (D1=A, page 63).
Operator A1 turning direction is checked using
parameter C1 and pushbuttons ST1 (open) and ST2
(close): when the display shows C101, with the first 1
flashing, press ST1 / ST2 to check turning direction.
A2 turning direction is checked in a similar manner,
using C201.
For further information, and to see how to change
turning direction, see parameters C1 and C2 in page
58.
D3 - D4
0 X
Select the value using
^ and
V
60), to
Control board VIVO-M203(M)