conductor shall be used for the connection – cable 3 x 2.5 mm² (cable 3 x
2.5 mm² for power > 3700W).
The electrical circuit supplying the appliance must have an in-built device
ensuring the splitting of all terminal poles under conditions of super-voltage
of category III.
To install the power supply wire to the appliances remove the plastic cover.
Connect the power wires in compliance with the marks on the terminals,
as follows:
the phase - to mark A, A1, L or L1;
the neutral - to N (B or B1 or N1)
The safety wire must be obligatory connected to the screw joint marked
with
.
ATTENTION! The power supply conductor insulation from fixed wiring
must be protected from direct contact with the flange (in zone under the
plastic panel). For example, insulating sleeving having temperature rating
higher than 90 °C can be used.
After the installation, put the plastic cover back in its place!
Explanations to Fig. 2:
TS - thermal switch; TR - thermal regulator; S - switch (for models that
have one); R - heater; IL - light indicator; F - flange; KL - luster terminal;
RUST PROTECTION MAGNESIUM ANODE (FOR WATER
VI.
HEATERS WITH WATER TANKS COVERED BY GLASS-CERAMICS
COATING)
The magnesium anode protects the water tank's inner surface from
corrosion.
The anode element is an element undergoing wear and tear and is subject to
periodic replacement.
In view of the long-term and accident free use of your water heater, the
manufacturer recommends periodic inspections of the magnesium anode's
condition by a qualified technician and replacement whenever required,
and this could be performed during the appliance's technical preventive
maintenance.
For replacements, please contact the authorized service stations!
OPERATION
VII.
Switch on:
1.
Before switching on the appliance for first time, make sure that the water
heater is properly connected to the power supply network and full with water.
The appliance is switched on by a switch integrated into the installation,
described in item 3.3 of Section V, or upon connecting the plug to the
electrical contact (in the case of an extension cable with plug).
Notice: Models with a built -in switch - it is necessary to switch it
on. There is an embossed marking on the button of the electrical switch
.
Water heaters with electromechanical control
2.
Fig. 2a and 2b where:
1 - Electrical switch button (for models with а switch)

2 - Light indicators

3 - Thermostat control knob (only for models with adjustable thermostat)
Push and release the button in order to switch on the electrical switch. If it
lightens, this means that it is switched on. The button lights constantly unless
the switch is switched off or the appliance power supply from electrical main
is switched off. The light indicators lighten too (see item 2.1. below).
In order to switch off the electrical switch, push and release the button
again. It must stop to light if it is switched off. The light indicators stop lighting
too.
Light indicators
2.1.
The indicators light in green color – means that the appliance is in SMART
mode.
The indicators light in red color – means that the appliance is in heating
mode
The indicators light in blue color – means that water is warmed and the
thermostat is switched off, because the set temperature is reached
The light indicators do not light when:
The electrical switch of the appliance is switched off
The appliance power supply from electrical main is switched off
Protection according to the temperature is switched off – see item 4 below
2.2.

Temperature setup (for models with adjustable thermostat)

This setup allows the gradual setting of the desired temperature, achieved by
using a handle on the control panel. Turn the knob to the upward indication,
in order to increase the temperature of the hot water.
Place the thermostat knob in position for maximum temperature
(unless it is on this position constantly), for period of one day each
month - see Annex-I (11) Maximum temperature of the thermostat. This
ensures higher hygiene of the used hot water.
IMPORTANT: Models that do not have thermostat control knobs
have automatic water temperature preset by the manufacturer -
see Annex-I (12) Default temperature settings.
e
Position
(Energy-save mode) – At this mode, water temperature reaches
English
up to approximately 60°С. Heat losses are reduced in this way.
Аnti-freezing" function
3.
Place the thermostat knob in position „Аnti-freezing" according to fig.2.
With this setup the device maintains temperature that does not allow the
water freeze in it.
The electrical supply of the appliance should be turned on and so must be
the appliance. The safety valve and the pipe between the valve and the
appliance must be protected from freezing. In case that for some reason the
electrical supply is cut off, there is a risk of freezing of the water in the water tank.
For this reason we recommend draining the water out of the appliance before long
absences (longer than a week).
Protection according to the temperature (valid for all models).
4.
The appliance is equipped with a special facility (thermal circuit-breaker) for
protection against over-heating of the water, which is switching off the heater
from the electricity network, when the temperature reaches too high values.
When this device operates, it does not self-reset and the appliance will
not work. Please call an authorized service for solving the problem.
MODELS EQUIPPED WITH A HEAT EXCHANGER (SERPENTINE
VIII.
TUBE).
These are appliances with inbuilt heat exchanger and are intended to be
connected to the heating system with maximum temperature of the heat
carrier of 80°C.
The control over the flow through the heat exchanger is a matter of solution
for the particular installation, whereby the choice should be made at its
design (e.g. external thermostat that measures the temperature in the water
tank and operates a circulation pump or a magnet valve).
Water heaters with a heat exchanger provide the opportunity for the water to
be heated in two ways:
by means of a heat exchanger (coil) – a primary way of heating the water,
1.
2.
by means of an auxiliary electrical heating element with automatic
operation, built in the appliance – it is used only when additional heating of
the water is needed or in case of repairs to the system of the heat exchanger
(coil). The proper way of connecting the appliance to the electric network and
how to work with it has been specified in the previous paragraphs.
Mounting:
In addition to the mounting manner outlined above, especially for the latter
models, it shall be required to connect the heat exchanger to the heating
installation. The connections are to be carried out in observance of the
direction indicated by the arrows on Fig. 1d÷Fig. 1f.
Technical parameters (table 5):
Surface of serpentine [m²] - S;
Volume of serpentine [l] - V;
Operational pressure of serpentine [MPa] - P;
Maximum temperature of heat carrier [°C] - Tmax.
We recommend you mount stopcocks at the heat exchanger's entry and exit
points. By stopping the flow of the thermophore via the lower (stopcock) you
shall avoid the unnecessary circulation of the thermophore during periods of
use only of the electric heating element.
Upon disassembly of you water heater equipped with a heat exchanger you
must close both stopcocks.
There is a connexion with internal thread of ½" welded to the water tank for
the purposes of installing thermal probe – marked with „TS". The appliance is
fitted with brass pocket for a thermal probe which should be screwed into the
aforesaid connexion.
The usage of dielectric bushings for connecting the heat exchanger
to an installation of copper pipes is obligatory.
For ensuring minimal corrosion, pipes with a limited diffusion of
gasses must be used in the installation.
PERIODIC MAINTENANCE
IX.
Under normal use of the heater, under the influence of high temperature, lime
scale /the so-called lime scale layer/ is deposited upon the heating element's
surface. This worsens the heat exchange between the heating element and
water. The heating element's surface temperature increases along /of boiling
water/. The thermoregulator begins to switch on and off more frequently.
A ''deceptive" activation of the thermal protection is possible. Due to these
facts, the manufacturer recommends preventive maintenance of your water
heater every two years by an authorized service center or service base. This
protective maintenance must include cleaning and inspection of the anode
protector (for water heaters with glass-ceramic coating), which shall be
replace with a new one if need arises.
In order to clean the appliances use a damp cloth. Do not clean with abrasive
or solvent content detergents. Do not pour water over the appliance.
The manufacturer does not bare the responsibility for all consequences
caused by not obeying the instructions, given hereby.
Instructions for protecting the environment
Old electric appliances contain precious materials and thus should
not be thrown together with the household litter. We kindly ask you
make your active contribution for protecting the resources and the
environment by handing over the appliance in the authorized buy-
back stations (if such exist).
EN
7
Instructions for use and maintenance

Advertenties

Inhoudsopgave
loading

Inhoudsopgave