The manufacturer cannot be made responsible for damages that are caused by a
missing or damaged protective conductor.
Adapters, multi-way strips and extension leads must not be used. Overloading can lead
to fire.
If the plug is no longer accessible following installation an all-pole isolating switch must
be present on the installation side with a contact gap of at least 3mm.
In accordance with the appropriate regulations, the socket must be installed and the
connecting cable must be replaced only by a qualified electrician.
13.5.3 Installation instruction
Please observe this special installation instructions.
The appliance can be installed inside a 60cm wide wall-mounted cupboard (at least
55cm deep and 85cm off the floor).
The built-in cabinet shall not have a rear wall behind the appliance.
Do not cover ventilation slots and air intake points.
Do not trap or kink the power cord. Make sure that the oven is installed in the center of the
cabinet. 30 mm free space is needed above the device top surface
59