5.5.3 Exemplary settings

Example 1 is the factory setting
ds-1
ds-2 Panel option
ds-3 Ch. voltage
ds-4 Ch. voltage
ds-5 Frequency
ds-6 Search mode
ds-7 AC-in Limit
ds-8 Store setting
Example 1: (factory setting)
1
No panel or remote
switch connected
2
No panel or remote
switch connected
3, 4
GEL 14.4 V
5
Frequency: 60Hz
6
Search mode off
7
AC-in Limit 30 Amp
8
store setting: off→
on→ off
Store the settings (ds-3 to ds-7) by changing switch ds-8 from 'off' to 'on', and then back to
'off'.
The LED's 'charger' and 'alarm' will flash to indicate acceptance of the settings.
6 Maintenance
The Compact does not require specific maintenance. It will suffice to check all connections
once a year. Avoid moisture and oil/soot/vapours, and keep the device clean.
off
ds-1
on
ds-2
off
ds-3
off
ds-4
off
ds-5
off
ds-6
off
ds-7
→ ←
ds-8
Example 2
1. No panel or remote
switch connected
2. No panel or remote
switch connected
3,4. AGM 14,7V
5. Frequency: 60Hz
6. Search mode off
7. AC-in Limit 50 Amp
8. store setting: off→
on→ off
off
ds-1
on
ds-2
off
ds-3
on
ds-4
off
ds-5
off
ds-6
on
ds-7
→ ←
ds-8
Example 3
1. Panel or remote
switch connected
2. Panel or remote
switch connected
3, 4. Tubular plate 15V
5. Frequency: 50Hz
6. Search mode on
7. AC-in Limit 30Amp
8. store setting: off→ on→
off
on
off
on
on
on
on
off
→ ←

Advertenties