Ventilation

Never cover the ventilation openings at the base of the
unit (front) or in the unit housing (top). Otherwise the
refrigerating unit has to work harder, which increases
power consumption.
The following dimensions must be used:
Depth of the ventilation shaft at the rear wall of the unit:
min. 38 mm
Ventilation cross−sections in the base of the unit and in
the unit housing (top):
2
min. 200 cm

Transporting the appliance

!
Warning!
Risk of injury from shards of glass.
During transport at a height of more than 1500 m,
the glass panels in the door can break. The
fragments of glass have sharp edges and can
cause serious injuries.
The appliance should be packed and kept upright for
transport.
Note!
To protect the glass door, only remove the
transportation lock once the appliance is in the
recess.
Fasten the transportation lock each time before the
appliance is transported.

Electrical connection

The socket for connecting the appliance must be freely
accessible. Connect the appliance to a
220 − 240 V/50 Hz alternating current supply via a
socket which has been correctly installed. The socket
must be fitted with a 10 to 16 A fuse.
Do not use any extension cables or distributors.
In the case of appliances operated outside Europe,
check whether the voltage and type of current
specified on the rating plate conform to the values
of your electricity grid. The rating plate is at the
bottom left inside the appliance. If the power cord
needs to be replaced, this must be carried out only
by an expert.
!
Warning!
The appliance must not be connected to an
electronic energy saving plug (e.g. Ecoboy; Sava
Plug) or an inverter that converts direct current to
230 V alternating current (e.g. solar energy systems,
boat electrical systems).