Taking the sample
6.2
Extracting the
smoke gas
Fig. 3: Extracting the smoke gas
22
Do 10 pump strokes as follows:
Pull out piston (20) slowly (in about 2-3 sec-
onds) and hold it in the final position for about
3 seconds, so that a pressure compensation
can be made.
ATTENTION!
Through the filter paper the pressure compensa-
tion can only take place slowly. Therefore it is ab-
solutely necessary to wait 3 seconds before
pressing the piston back.
Press the piston back.
Repeat this procedure 10 times.
ATTENTION!
Waiting times, with pulled up piston should strictly
be kept, so that the pump can draw the right
amount of flue gas.
Take the measuring head with the extraction
probe (1) out of the check opening.
Remove the clamps (3) from the probe con-
nector (4).
Remove the filter paper and analyze the soot-
spot on the paper as explained in chapter 5.3
.
NOTE!
The excentrical check opening of the measuring
head (2) allows several tests with the same paper
moving the filter paper.