4
Technical data
Max. charging power [kW]
Rated current I
[A]
nA
Rated current of a charging point
Mode 3 I
[A]
nC
Max. back-up fuse [A]
Conditional rated short-circuit
current I
[kA]
cc
AMTRON® Professional(+) E 3,7 / 11, Professional(+) (E) 7,4 / 22 (PnC)
Connection
Nominal voltage U
[V] AC ±10 %
N
Nominal frequency f
N
Nominal insulation voltage U
Nominal impulse withstand voltage U
Nominal diversity factor RDF
Types of system earthing
EMC classification
Protection class
IP rating
Overvoltage category
Mechanical impact protection
Contamination rating
Installation
Stationary / movable
Use (according to IEC 61439-7)
External design
Dimensions H x W x D [mm]
Weight [kg]
Standard
The specific standards according to which the product was tested can be found in the declaration of con-
formity for the product. The declaration of conformity can be found on our website in the download section
for the selected product.
14
AMTRON® Professional(+) E 3,7 /
11
3.7 / 11
16
16
16
10
[Hz]
[V]
i
[kV]
imp
AMTRON® Professional(+) (E) 7,4 /
22 (PnC)
7.4 / 22
32
32
Product with circuit breaker: 80;
product without circuit breaker:
32
10
single phase / three phase
230 / 400
50
500
4
1
TN / TT (IT under certain conditions)
A+B
I
Product with charging cable or shutter: IP 44;
product with hinged lid: IP 54
III
IK10
3
Outdoor or indoor
Stationary
ACSEV
Wall mounted
475 x 259 x 220
Product with charging cable: 8; product with
charging socket: 5.5
IEC 61851, IEC 61439-7