4. Installation
• Remove the packaging and place the induction heater on a non-ferrous, stable and level
surface. Put heaters with wheels on the brake to prevent the heaters from moving.
• Check the connection voltage against the rating plate on the unit.
• Each heater is equipped with a plug. As there is a wide variety of plug types, the provided
plug may not fit. In such cases, obtain a proper plug. It must be fitted by a qualified
electrician. There are different fitting options depending on the type of cable on the heater:
Fitting options BLF 200 - 203
120V/230V 1 phase heaters
Brown
Blue
Green/Yellow Ground
Fitting options BLF 204 - 208
400V/450V/500V 2 phase heaters
Brown
Black
Green/Yellow Ground
• Ensure that the power supply cable cannot come into contact with the workpiece to be
heated. Insert the plug in a grounded socket outlet with connection.
• Switch on the device by means of the main switch. The machine briefly shows "Test", and
the display shows a "pre-set end temperature" programmed by the manufacturer.
• Connect the temperature sensor by inserting the plug into the socket. Make sure that the
– and + of the plug correspond to that of the socket.
• The induction heater is now ready for use in the temperature mode.
12
120V/240V 1 phase heaters
Phase
Zero
480V/600V 2 phase heaters
Phase
Phase
Black
Phase
White
Zero
Green
Ground
Black
Phase
Black
Phase
Green
Ground
© BETEX Tools