Download Inhoudsopgave Inhoud Print deze pagina

Scope Of Delivery - Wilo -HiControl 1 Inbouw- En Bedieningsvoorschriften

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 36
English
5.2
Dimension drawing
Fig. 2: Side view - manometer side
Fig. 3: Front view
Fig. 4: Top view
5.3 Product description (Fig. 5)
1 - Discharge port, 1"
2 - "Power on" indicator light
3 - "Safety system activated" indicator light
4 - "Pump operating" indicator light
5 - RESET button
6 - Connection cables with cable ends depending on version (Fig. 7 or 8)
Fig. 7: Mains cable
(HiControl 1-ARS version)
Fig. 8: Mains cable with female shockproof plug
(HiControl 1-EK version)

5.4 Scope of delivery

HiControl 1
• HiControl 1 automatic pump control system, no cord
• Bag containing two threaded cable connections
• Instruction manual
HiControl 1-EK
• HiControl 1-EK automatic pump control system, mains cable with female
shookproof plug
• Bag containing two threaded cable connections
• Instruction manual
HiControl 1-ARS
• HiControl 1-ARS automatic pump control system, mains cable with Australian plug
• Bag containing two threaded cable connections
• Instruction manual
6 Description and function
• The HiControl 1 automatic pump control system is a device which protects the
pump in the event of low water. It also controls the starting and stopping of the
pump based on the system pressure/flow conditions.
• When a tap is turned on, the pressure in the system falls, and the pump
immediately starts working at the factory preset 1.5 bar. The pump continues to
operate as long as there is a minimum flow (> 95 l/h) in the pipes. When the tap is
turned off, the pump will automatically stop after a 10-second time delay.