5. TROUBLESHOOTING
5.1. Sheeter will not run.
• Verify if the main switch is on.
• Verify whether the conveyor belts and protective guards are in the
proper positions.
• Check power plug for proper insertion.
• Have a certified electrician verify all power connections, and double
check proper connection of the neutral wire.
• Check all fuses in the circuit.
• Check micro switches.
5.2. Sheeter runs intermittently
• Check plug for poor contacts or loose wires.
• Check power cord for damage.
• Check power circuit for current fluctuations.
• Check protective guards for proper adjustment, adjust limit switches
located under the back cover if necessary.
5.3. Rollers will not pull dough through
• Re-tension v-belts from the motor to the machine.
5.4. Conveyor belts slip
• Re-tension v-belts from the motor to the machine.
5.5. Reverse conveyor belt does not operate
• Check appropriate switches.
• Check v-belt tension.
5.6. Machine hums and does not operate or has low power
• Have an electrician verify if motor is operating on all 3 phases.
• Check all fuses in the circuit.