Download Inhoudsopgave Inhoud Print deze pagina

Storage Instructions - medi Lumbamed disc Gebruiksaanwijzing

Lumbar support with adjustable stabilisation system
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 17
English
over each other as far at the same
distance. When fastening, ensure that
the back brace is in the middle. The
orthotic is on properly when the lower
fastener edge is just above the pubic
bone (see Fig. 9) (Fig. 6 + 7).
• Now unfasten the hook and loop ends
of the pull straps and pull these
forward at the same time. You can
adjust the tightness to suit your own
requirements and manage your pain
levels (Fig. 8 ) .
• Information for technicians: The strap
length may be adjusted by cutting it at
the edge of the Y fastener (Fig. 10).
Removing / Changing the stabilising
rods
Hold the lower end of the rod and pull it
slightly downwards with the knitted
fabric. At the same time, slightly pull
apart the upper opening in the knitted
fabric. You can now remove the rod
easily from the pocket. For inserting the
rods, slide them into the individual
pockets again and reposition them in
the same way.
Care instructions
Before washing, please remove the
internal rods (cf. Fig. 12) as well as the
strap supporting system by detaching it
from the Y connecting piece (cf. Fig. 11).
During replacement make sure that the
medi logo on the back stays is at the top.
Hook and loop tabs must be closed for
washing.We recommend using a laundry
bag. Fabric softeners, fats, oils, lotions,
ointments and soap residues can affect
the material, hinder the Clima Comfort
effect and cause skin irritations.
• Wash the product by hand, preferably
using a medi clean detergent, or in
delicate cycle at 30°C using a mild
detergent without fabric conditioners.
• Do not bleach.
• Leave to dry naturally.
• Do not iron.
• Do not dry clean.
  

Storage instructions

Keep the product in a dry place and do
not expose to direct sunlight.
Composition
Polyamide, Polyester, elastan, ABS
Plastic
Liability
The manufacturer's liability will become
void if the product is not used as
intended. Please also refer to the
corresponding safety information and
instructions in this manual.
Disposal
The product can be disposed of
in the domestic waste.
Your medi Team
Wishes you a rapid recovery!
In the event of any complaints regarding
the product such as damage to the fabric
or a fault in the fit, please report to your
specialist medical retailer directly. Only
serious incidents which could lead to a
significant deterioration in health or to
death are to be reported to the
manufacturer or the relevant authorities
in the EU member state. The criteria for
serious incidents are defined in Section
2, No. 65 of the Regulation (EU) 2017/745
(MDR). The traceability of this product is
assured via a UDI code
 .

Advertenties

Inhoudsopgave
loading

Inhoudsopgave