Download Inhoudsopgave Inhoud Print deze pagina

BFT THALIA P Installatievoorschriften pagina 36

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 72
x2
***
0---
10--
ALT
follow the user guide
add. start
Add. 2ch
erase 64
language
autoset
LUX BT / LUX G BT
l. s w adj
opm1
2
opm2
2
clm2
2
clm1
2
ersu
o
Control unit
software version
stat
OK
vers
- +
No total manoeuvres(in hundreds)
OK
n. cycles
- +
No radio controldevices memorised
n. remotes
OK
- +
List of last 30 errors
err
OK
0---
password
36 -
THALIA P
ACCESS MENUS Fig. 1
INSTALLATION MANUAL
150-
1520
See PARAMETERS MENU
See LOGIC MENU
hidden butt
release
desired button
hidden butt
release
desired button
See RADIO MENU
Diagnostics
code
STRE
STRI
OPEN
CLS
PED
TIME
STOP
PHOT
PHOP
PHCL
BAR
baro
barc
GIUNO ULTRA
SWC1
SWO1
SWC2
Manual movement
1
SWO2
2
1
SET
1
-
2
1
ER01
-
1
ER02
ER03
ER04
-
1
er06
ER07
ER08
+/-
ER1x*
bft . . .
+/-
ER2x*
ER3x*
0000
ER4x*
+/-
ER5x*
00
ER7x*
+/-
ERf3
ERF9
01. 3 3
02. 0 1
Ersw
........
30. 1 5
+/-
10--
150-
*** Password entry.
ok
Request with Protection Level
logic set to 1, 2, 3, 4
DESCRIPTION
START E external start input activated
START I internal start input activated
OPEN input activated
CLOSE input activated
PED pedestrian input activated
TIMER input activated
STOP input activated
Activation of PHOT photocell input or, if configured as
verified photocell, Activation of the associated FAULT input  
Activation of PHOT OP opening photocell input or, if
configured as active verified photocell only when opening,
Activation of the associated FAULT input
Activation of PHOT CL closing photocell input or, if configured
as active verified photocell only when closing, Activation of
the associated FAULT input
Activation of BAR safety edge input or, if configured as
verified safety edge, Activation of the associated FAULT input  
Activation of BAR safety edge input with ACTIVE reversal ONLY
WHILE OPENING, or, if configured as verified safety edge active
only while opening, Activation of the associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY
WHILE CLOSING, or, if configured as verified safety edge active
only while closing, Activation of the associated FAULT input
SWC1 motor 1 closing limit switch input activated
SWO1 motor 1 opening limit switch input activated
SWC2 motor 2 closing limit switch input activated
SWO2 motor 2 opening limit switch input activated
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in order
to acquire the torque required for movement.
WARNING! Obstacle detection not active
Photocell test failed
Safety edge test failed
Opening photocell test failed
Closing photocell test failed
8k2 safety edge test failed
Opening safety edge test failed
Closing safety edge test failed
Board hardware test error
Encoder error
Reverse due to obstacle - Amperostop
Thermal cutout
Communication error with remote devices
Internal system supervision control error.
Error in setting the SAFE inputs
Solenoid lock output overload
Error during limit switch adjustment
Only for Lux BT e Lux-G BT
*X= 0, 1, .., 9, A, B, C, D, E, F
1520
prg
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
35. 4 0
Instantaneous force motor 2
Instantaneous force motor 1
NOTES
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
- Check connections to motor
- Hardware problems with board (contact technical
assistance)
- Motor power or encoder signal cables inverted/disconnected.
- Actuator movement is too slow or stopped with respect
to programmed operation.
Check for obstacles in path
Allow automated device to cool
Check connection with serial-connected accessory
devices and/or expansion boards
Try switching the board off and back on again. If the prob-
lem persists, contact the technical assistance department.
Check the setting of the SAFE inputs is correct
-Check lock connections
- Unsuitable lock
- Repeat the limit switch adjustment procedure.
- Try moving the maximum limits of both the opening
and closing limit switches.
- Caution: the last centimetre of the piston's stroke,
during either opening or closing, cannot be used.
 

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Thalia

Inhoudsopgave