Set-up, gas and electricity connection
Gas connection
Installation must only be performed by an approved expert or a
licensed after-sales service engineer in accordance with the
instructions specified under "Gas connection and conversion to
a different gas type".
For the licensed expert or after-sales service
Caution!
The setting conditions for this appliance are specified on the
■
rating plate on the back of the appliance. The gas type set in
the factory is marked with an asterisk (*).
Before setting up the appliance, check the grid access
■
conditions (gas type and gas pressure) and ensure that the
gas setting of the appliance meets these conditions. If the
appliance settings have to be changed, follow the instructions
in the section "Gas connection and conversion to a different
gas type".
This appliance is not connected to a waste gas main. It must
■
be connected and commissioned in accordance with the
installation conditions. Do not connect the appliance to a
waste gas main. All ventilation regulations must be observed.
The gas connection must be made via a fixed, i.e. not mobile
■
connection (gas line) or via a safety hose.
If using the safety hose, ensure that the hose is not trapped
■
or crushed. The hose must not come into contact with hot
surfaces.
The gas line (gas pipe or safety hose) can be connected to
■
the right or left-hand side of the appliance. The connection
must have an easily accessible locking device.
Faults in the gas installation/smell of gas
If you notice a smell of gas or faults in the gas installation, you
must
immediately shut off the gas supply and/or close the gas
■
cylinder valve
immediately extinguish all naked flames and cigarettes
■
switch off electrical appliances and lights
■
open windows and ventilate the room
■
call the aftersales service or the gas supplier
■
Moving the appliance by the gas line or door
handle
Do not move the appliance while holding the gas line; the gas
pipe could be damaged. There is a risk of a gas leak! Do not
move the appliance while holding it by the door handle. The
door hinges and door handle could be damaged.
Electrical connection
Caution!
Have the appliance set up by your after-sales service. A 16 A
■
fuse is required for connection. The appliance is designed for
operation at 220-240 V.
If the electricity supply drops below 180 V, the electrical
■
ignition system does not work.
Any damage arising from the appliance being connected
■
incorrectly will invalidate the guarantee.
If the supply cord is damaged, it must be replaced by the
■
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
For the after-sales service
Caution!
The appliance must be connected in accordance with the
■
data on the rating plate.
Only connect the appliance to an electrical connection that
■
meets the applicable provisions. The socket must be easily
accessible so that you can disconnect the appliance from the
electricity supply if necessary.
Please ensure the availability of a multi-pin disconnecting
■
system.
Never use extension cables or multiple plugs.
■
For safety reasons, this appliance must only be connected to
■
an earthed connection. If the safety earth terminal does not
comply with regulations, safety against electrical hazards is
not guaranteed.
You must use a H 05 W-F type cable or equivalent for the
■
appliance connection.
Levelling the cooker
Always place the cooker directly on the floor.
Pull out the plinth drawer and lift it up and out.
1.
There are adjustable feet at the front and rear on the inside of
the plinth.
Use an Allen key to raise or lower the adjustable feet as
2.
necessary until the cooker is level (picture A).
Push the plinth drawer back in (picture B).
3.
$
Wall fixing
To prevent the cooker from tipping over, you must fix it to the
wall using the enclosed bracket. Please observe the installation
instructions for fixing the oven to the wall.
%
7