3.16. INFORMATION Menu

Press
for quick access to the information menu from the main screen.
User menu
7/8
Pool
Information
Alarms
7/8
Brine/Production
Brine
Outlet:

Inlet:
5
DT:
3
Press:

Pumps:
95
7/8
Production
Outd
Outlet:

Inlet:
5
DT:
3
Press:

Pumps:
95
Boiler
State

RealT:
Regulation:
Outdoor temperature
OutdoorT:
47
Outdoor StopT
Heating:
Active cool:
Passive cool:
Room terminals
SetT
RealT


T:
5
498
T:
45
4
T3:
45
43
T4:
35
35
Inercia XXXXXX
Treal:
Tconsigna:
DTinicio:
XXXXXX groups
SetT
RealT


DG: 5
498
SG: 45
4
SG3: 45
43
SG4: 35
35
DHW
RealT:
3
SetT:
DTstart:
94
Start comp T:
Brine/Production (ecoGEO)
Heat
35 
This shows the inlet and return temperatures, temperature difference, current pressure
99 
5 
and the percentage of circulator pump regulation in the brine and production circuits or
shows the simultaneous production valves regulation value.
4 bar
87
%
Production (ecoAIR)
Ind
35 
This shows the inlet and return temperatures, temperature difference, current pressure
99 
and the percentage of circulator pump regulation outdoors and indoors module.
5 
4 bar
87
%
Boiler
Off
Shows whether the boiler is On or Off, the current temperature in the support with boiler
4
sensor and the regulation percentage of the boiler or the mixing valve.
%
Outdoor temperature
47
Shows the current outdoor temperature and the outside temperatures for heating and
cooling cut-off.

8
3
Room terminals
RH
%
In installations with interior terminals equipped with bus communication (Th-tune, Th-T or
3

TH sensors), it displays the interior setpoint temperature (Tcons), the current temperature
3
(Treal) and the current relative humidity (HR) of the terminals assigned to each outlet unit.
94
Heating buffer / Cooling buffer
This shows the setpoint temperature, the start-up temperature differential and the current
499
temperature of the buffer storage tank.
5
There are separate screens for the heating and cooling buffer storage tanks.
5
Heating groups / Cooling groups
Reg
%
This shows the target outlet temperature (SetT), the current outlet temperature (RealT)
and the regulation percentage (Reg) of each outlet unit.

3
There are separate screens for the heating and cooling outlet units.
94
DHW
479
This shows the setpoint temperature, the start-up temperature differential and the current
48
temperature of the DHW storage tank.
5
43
47