Activation of the various OPERATING MODES may be affected by the time schedule functions or heat
pump service priorities (DHW, HEATING, COOLING, POOL).
NOTE
The activation of the HEATING and COOLING operating modes may be affected by service shut down
temperatures.
Apart from the icons that define the operating modes, the following icons can also be found in this field.
Operation
This indicates thermal energy transfer between circuits.
If the icon is shown continuously, this indicates normal heat pump operation.
If the icon flashes, there is a heat pump protection activated.
Energy source
Power removal or injection at the energy source.
Cycle inversion
The HEAT/COLD production cycle is being inverted. Only for reversible heat pumps.
Wait
Compressor start-up is deactivated due to standby between start-ups. The minutes remaining for the compressor
to start up are shown next to the icon.
STAND
No demand. The heat pump remains in standby because there is no demand.
-BY

3.5. Operation program

The heat pump operation program determines which operation modes can be activated.
WINTER program
The heat pump does not allow activation of the PASSIVE COLD and ACTIVE COLD operating modes.
SUMMER program
The heat pump does not allow activation of the HEATING operating mode.
COMBINED program
The heat pump allows activation of any operating mode.
AUTO program
The heat pump automatically switches between the WINTER/SUMMER operating programs, depending on the
outside temperature. The temperatures and time required for the switch must be adjusted by the user.
REMOTE Control
WINTER / SUMMER program selection is triggered by an external signal.