5.2.5. DHW/LEGIONELLA PROT. Menu
User menu
5/8
ooling
DHW/Legionella prot
Pool
5/9
DHW
Enable:
External boiler
Emergency:
Support:
5.2.6. POOL Menu
User menu
/8
DHW/Legionella prot
Pool
Information
/9
Pool
Enable:
External boiler
Emergency:
Support:
5.2.7. e-MANAGER menu
User menu
7/9
e-Manager
Information
Alarms
7/9
Surplus control
Enable:
onsumption control
Enable:
onsump limit:
DHW
Used to enable the DHW mode.
External BOILER
This is used to enable the auxiliary boiler in both EMERGENCY and SUPPORT mode.
In EMERGENCY mode, the auxiliary system is activated automatically when any of the
alarms are active.
In SUPPORT mode, the auxiliary system is activated automatically for normal DHW
production, as programmed by the technical service.
Pool
Used to enable the POOL mode.
External BOILER
This is used to enable the auxiliary boiler in both EMERGENCY and SUPPORT mode.
In EMERGENCY mode, the auxiliary system is activated automatically when any of the
alarms are active.
In SUPPORT mode, the auxiliary system is activated automatically for normal POOL
production, as programmed by the technical service.
Surplus control
Used to enable the surplus electricity control.
The surplus control attempts to adjust the network balance (consumption and injection)
to the value set in the installer menu at all times.
Consumption limit
Used to enable the electrical consumption control.
3kW
Used to set the maximum overall consumption value of the electrical installation by
means of the heat pump power control.
e-SUPERVISOR ecoSMART heat pump block manager
32
Control applications manual