10 -
ALCOR AC A
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
memorized in standard mode via the radio menu.
ON
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters.
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters and automatic addition of clones.
OFF
Transmitters are memorized only using the relevant Radio menu or automatically with replays.
IMPORTANT: Disables the automatic addition of new transmitters and clones
Input configured as Bar 8k2 (Fig.G). Input for resistive edge 8K2.
ON
The command reverses movement for 1 sec.
Input configured as Bar, safety edge (Fig.G).
OFF
The command reverses movement for 1 sec..
ON
Enable safety check on the PHOT input. (Fig.G)
OFF
Safety check on PHOT input not enabled. (Fig.G)
ON
Enable safety check on the BAR input. (Fig.G)
OFF
Safety check on BAR input not enabled. (Fig.G)
In the event beam is broken, photocell operation is disabled during opening. During closing, move-
ON
ment is reversed immediately.
When
beam
is
OFF
sing. When beam is broken during closing, movement is reversed only once the
photocell is cleared.
ON
Safety edge with active reversal only when closing, when opening the movement stops
OFF
Safety edge with active reversal in both directions
ON
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
OFF
Logic not enabled
Sets the
automation type
ON
of operation:
ON = Apartment building
OFF
OFF = Residential
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the sole-
ON
noid lock to be released more easily.
OFF
Logic not enabled
If motors stay idle in fully open or fully closed position for more than one hour, they are switched on
in the direction of the stop for approx. 3 seconds. This operation is performed every hour.
NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil
ON
due to a drop in temperature during extended pauses, such as during the night, or due to internal
leakage.
OFF
Logic not enabled
broken,
photocells
are
active
Reaction to the
input (wired or radio):
CLOSED
Opens
WHILE CLOSING Stops
OPEN
Closes
WHILE OPENING STOPS + TCA
AFTER STOP
Opens
Reaction to the
input (wired):
CLOSED
Opens
WHILE CLOSING Opens
OPEN
Keep open + TCA
WHILE OPENING No effect
AFTER STOP
Opens
Reaction to the
CLOSED
Opens partially
WHILE CLOSING Stops
OPEN
Closes
WHILE OPENING STOPS + TCA
AFTER STOP
Opens partially
during
both
opening
and
Opens
Opens
Closes
No effect
Opens
Opens
Opens
Keep open + TCA
No effect
Opens
input (radio):
Opens partially
Opens partially
Closes
No effect
Opens partially
clo-