L
LINE
N
NEUTRAL
10
START + CONDENSER
11
COM
12
START + CONDENSER
14
START + CONDENSER
15
COM
16
START + CONDENSER
20
AUX 0 – POWERED CONTACT
230V (N.O.) (40W MAX)
21
50
0V-
51
24V+
52
24 Vsafe+
60
Common
61
START
62
OPEN
70
Common
71
STOP
72
PHOT (*)
73
FAULT 1
BAR /
BAR CL /
BAR TEST /
74
BAR CL TEST /
BAR 8K2 /
BAR CL 8K2
(*)
75
FAULT 2
Y
ANTENNA
#
SHIELD
0
120
5
90
50%
0
25
25%
Single-phase power supply
Motor and condenser connection
Connection between motor and capacitor 2.
Exit due to FLASHING LIGHT
Contact stays closed while leaves are operating.
Accessories power supply output.
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output act ive only during operating cycle.
START and OPEN inputs common
START command button (N.O.).
Operation according to "Residential / apartment building operation" logic
OPEN command button (N.O.).
Gate opened with this command. If the input stays closed, the leaves stay open until the
contact is opened.
When the contact is open, the automated device closes following the TCA time, where
activated.
STOP, PHOT and BAR inputs common
The command stops movement. (N.C.)
If not used, leave jumper inserted.
PHOTOCELL input (N.C.).
Operation according to "PHOTOCELL/PHOTOCELL DURING CLOSING" logic. If not used, leave
jumper inserted.
Test input for safety devices connected to PHOT.
Safety edge input (N.C.).
If not used, leave jumper inserted
dip
dip
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
Test input for safety devices connected to BAR / BAR CL
Antenna input.
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver.
Metal bodies close to the antenna can interfere with radio reception. If the transmitter's
range is limited, move the antenna to a more suitable position.
Waiting time before automatic closing.
0
Motor 1 closing delay time with respect to motor 2.
dip
NC input, no verification, reversal while
OFF
opening and closing
ON
NC input, no verification, reversal only
when closing, stop when opening
OFF
NC input, with verification, reversal
while opening and closing
ON
NC input, with verification, reversal only
when closing, stop when opening
OFF
8K2 input, reversal when opening and
closing
ON
8K2 input, reversal only when closing,
stop when opening
9