The
control panel comes with standard factory settings.
Any change must be set by means of the TRIMMER and DIP SWITCH settings.
Its main features are:
- Checking of 2 single phase motors
- Separate inputs for safeties
- Rolling-code in-built radio receiver.
The board has a terminal strip of the removable kind to make maintenance or re-
placement easier. It comes with a series of prewired jumpers to make the installer's
job on site easier.
The
panel controls (checks) the start relays and safety devices
(photocells) before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
Power supply
Panel dimensions
Low voltage/mains insulation
Operating temperature range
Dielectric rigidity
Accessories power supply
AUX 0 - Flashing
Contact powered
Fuses
Built-in Rolling-Code
radio-receiver
Setting of parameters and logicsTRIMMER + DIP SWITCH
Max. n° of remotes that can be
memorized
Maximum power
Maximum work time
Install the electrical system referring to the standards in force for electrical systems
CEI 64-8, IEC 364, harmonization document HD 384 and other national standards.
Once suitable electric cables have been run through the raceways and the auto-
mated device's various components have been fastened at the predetermined
points, the next step is to connect them as directed and illustrated in the diagrams
contained in the relevant instruction manuals. Connect the live, neutral and earth
wire (compulsory).
When performing wiring and installation, refer to the standards
in force and, whatever the case, apply good practice principles. Wires carrying
different voltages must be kept physically separate from each other, or they must
be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devi-
ces such as cable clamps. All connecting cables must be kept far enough away
from dissipaters.
The values of the impact force according to EN 12453 are only observed with
the use of safety edges (active) connected to the board.
- Before turning the unit on, check electrical connections.
- Set the following parameters:
Automatic Closing Time,
Phase shift timing while closing
- Set the logics.
8 -
ALCOR AC A
110-120V 50/60Hz
220-230V 50/60 Hz
> 2MOhm 500V
-20 / +50°C
mains/LV 3750V~ for 1 minute
4V~ (demand max. 0,2A)
120V~ 40W max
230V~ 40W max
frequency 433.92MHz
63
750W
90s
associates the desired key with the Start command.
associates the desired key with the pedestrian command.
Confirms the changes made to parameter settings and operating
Erases all memorized transmitters from the
receiver's memory.
Steadily lit: - Mains power on - Board powered - Fuses intact
Lit: START input activated
Lit: OPEN pedestrian input activated
Unlit: STOP input activated
Unlit: PHOT photocell input activated
PHOT input safety device test input diagnostics
Unlit: BAR safety edge input activated
BAR input safety device test input diagnostics
Unlit: no error
LIT: see error diagnostics table
Unlit: remote programming not active
Radio LED only flashing: Remote programming active, waiting for
hidden key.
Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key.
Lit 1s: Radio receiver channel activated
Lit: see error diagnostics table
Flashing in sync with Radio LED: Transmitter deletion in progress
Photocell test,
Costa o Costa 8k2
failed
- Check photocell
connection and/
or logic settings
Reverse due to
obstacle - Ampe-
rostop
- Check for obsta-
cles in path
Test hardware
card error
- Check the
connection to the
motor
- Hardware pro-
blems to the card
(contact technical
assistance)
Changed settings
and/or Operating
logics press S2 for
5s to confirm.